Worked example
Example: Illustrative 1500 pcm, 3.66 m core, 1.2 m out. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Total rod worth (pcm) | 1,500.0 - |
| Core height | 3.6600 m |
| Rod withdrawal from the bottom (fully inserted = 0) | 1.2000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Worth withdrawn so far (pcm) | 281.08 |
| Worth still inserted (pcm) | 1,218.9 |
| Differential worth (pcm per cm) | 6.0245 |
| Fraction of total worth withdrawn | 18.739 % |
Open this example in the calculator and change any input.
Formula
\(\frac{\rho(z)}{\rho_T} = \frac{z}{H} - \frac{1}{2\pi}\sin\frac{2\pi z}{H}, \quad \frac{d\rho}{dz} = \frac{\rho_T}{H}\left(1 - \cos\frac{2\pi z}{H}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho_T\) | Total rod worth (pcm) | - |
| \(H\) | Core height | m |
| \(z\) | Rod withdrawal from the bottom (fully inserted = 0) | m |
| \(\rho(z)\) | Worth withdrawn so far (pcm) | - |
| \(\rho_T - \rho(z)\) | Worth still inserted (pcm) | - |
| \(d\rho/dz\) | Differential worth (pcm per cm) | - |
| \(\rho(z)/\rho_T\) | Fraction of total worth withdrawn | - |
Method and standards
Rod worth curve.
Where it is used
- Start-up and rod calibration planning.
- Reactor operator training.
Common mistakes
- Assuming worth is linear with withdrawal.
- Ignoring interaction between rod banks.
Assumptions and limits
- Bare core, cosine axial flux, small perturbation.
References
- Control rod worth by perturbation theory in a cosine flux
Questions and answers
Why is a rod most effective at mid-height?
Worth goes with the square of the local flux, which peaks in the middle of the core.
Why is it called an S-curve?
Integral worth against withdrawal rises slowly at the ends and steeply in the middle, tracing an S.
What do the defaults represent?
An illustrative 1,500 pcm rod in a 3.66 m core, withdrawn 1.2 m.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 7