Worked example
Example: Illustrative finite cylinder 3000 MW, 30 m3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Core shape | Finite cylinder |
| Core thermal power | 3,000.0 MW |
| Core volume | 30.000 m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Peak-to-average flux ratio | 3.6382 |
| Average power density | 100.00 MW/m³ |
| Peak power density | 363.82 MW/m³ |
Open this example in the calculator and change any input.
Formula
\(\Omega_{slab} = \frac{\pi}{2}, \quad \Omega_{sphere} = \frac{\pi^2}{3}, \quad \Omega_{cyl} = \frac{2.405}{2J_1(2.405)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{shape}\) | Core shape | - |
| \(P\) | Core thermal power | W |
| \(V\) | Core volume | m³ |
| \(\Omega\) | Peak-to-average flux ratio | - |
| \(\bar q'''\) | Average power density | W/m³ |
| \(q'''_{max}\) | Peak power density | W/m³ |
Method and standards
Flux shape factors.
Where it is used
- First estimates of peak power density.
- Teaching core design.
Common mistakes
- Using bare-core factors for reflected, zoned cores.
- Confusing peak-to-average with radial-only factors.
Assumptions and limits
- Bare homogeneous core; one group.
References
- One-group fundamental-mode flux shapes
Questions and answers
Why is a bare cylinder's peak 3.6 times the average?
The flux falls to near zero at all surfaces, cosine-like along the axis (π/2) and Bessel-like across the radius (2.32); the product is 3.64.
How do designers flatten the flux?
With reflectors, higher enrichment or fresh fuel near the edge, and burnable poisons in the centre.
What do the defaults represent?
An illustrative 3,000 MW finite cylindrical core of 30 m³.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 6