Worked example
Example: Illustrative PWR subchannel, 30 kW/m peak. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Peak linear heat rate (at mid-height) | 30.000 kW/m |
| Heated length | 3.6600 m |
| Extrapolated length of the cosine (≥ L) | 3.9000 m |
| Coolant flow in the channel | 1,080.0 kg/h |
| Coolant specific heat | 5.8000 kJ/(kg·K) |
| Coolant inlet temperature | 292.00 °C |
| Rod outer diameter | 9.5000 mm |
| Coolant heat transfer coefficient | 35,000 W/(m²·K) |
| Centreline-to-clad-surface temperature difference at the peak | 1,200.0 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Coolant outlet temperature | 334.61 °C |
| Height of the maximum clad temperature above mid-height | 0.79507 m |
| Maximum clad surface temperature | 349.12 °C |
| Height of the maximum centreline temperature above mid-height | 0.021622 m |
| Maximum fuel centreline temperature | 1,542.2 °C |
| Channel power | 74.137 kW |
Open this example in the calculator and change any input.
Formula
\(T_m(z) = T_{in} + \frac{q'_0L_e}{\pi\dot mc_p}\left[\sin\frac{\pi z}{L_e} + \sin\frac{\pi L}{2L_e}\right], \quad \tan\frac{\pi z_{max}}{L_e} = \frac{L_e}{\pi\dot mc_pR}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q'_0\) | Peak linear heat rate (at mid-height) | W/m |
| \(L\) | Heated length | m |
| \(L_e\) | Extrapolated length of the cosine (≥ L) | m |
| \(\dot m\) | Coolant flow in the channel | kg/s |
| \(c_p\) | Coolant specific heat | J/(kg·K) |
| \(T_{in}\) | Coolant inlet temperature | K |
| \(D\) | Rod outer diameter | m |
| \(h\) | Coolant heat transfer coefficient | W/(m²·K) |
| \(\Delta T_{f,0}\) | Centreline-to-clad-surface temperature difference at the peak | K |
| \(T_{out}\) | Coolant outlet temperature | K |
| \(z_c\) | Height of the maximum clad temperature above mid-height | m |
| \(T_{co,max}\) | Maximum clad surface temperature | K |
| \(z_f\) | Height of the maximum centreline temperature above mid-height | m |
| \(T_{cl,max}\) | Maximum fuel centreline temperature | K |
| \(P_{ch}\) | Channel power | W |
Method and standards
Chopped-cosine channel analysis.
Where it is used
- Hot channel analysis in core design.
- Teaching reactor thermal hydraulics.
Common mistakes
- Placing the clad maximum at mid-height.
- Using the core-average flow for the hot channel.
Assumptions and limits
- Single phase; constant properties; no cross-flow between channels.
References
- Axial temperature distribution in a heated channel with a chopped-cosine heat flux
Questions and answers
Why is the maximum clad temperature above mid-height?
The coolant keeps heating up along the channel, so the hottest clad sits downstream of the peak heat flux, where the falling flux and rising coolant temperature balance.
Why is the centreline maximum nearer mid-height?
The fuel temperature drop is large and follows the heat flux, so the coolant rise matters less.
What do the defaults represent?
An illustrative PWR subchannel: 30 kW/m peak, 3.66 m heated length, 3.9 m extrapolated, 0.30 kg/s, c_p 5,800 J/(kg·K), inlet 292 °C and a 1,200 K fuel drop at the peak.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 13