FireCADCalc

Thermal Neutron Diffusion Time and Prompt Lifetime

Thermal neutron diffusion (absorption) time of a medium from its 2,200 m/s absorption cross-section, and the prompt neutron lifetime of a finite core with leakage.

Thermal power plant

Inputs

Examples: Illustrative water, B2 0.003Graphite infinite mediumHeavy water small core

Accepted: 1E-6 to 100 1/cm
Accepted: 0.01 to 10,000 cm²
Accepted: 0 to 0.1
Accepted: 0 to 1,000 µs

Results

For a 1/v absorber vΣ_a is constant, so t_d = 1/(v₀Σ_a,0) with v₀ = 2,200 m/s whatever the temperature. Leakage shortens the lifetime: ℓ = t_d/(1 + L²B²). Slowing-down time is small in water but matters in graphite.

Diffusion time in an infinite medium230.73µs
Prompt neutron lifetime with leakage235.26µs
Thermal non-leakage probability97.628%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative water, B2 0.003. The inputs, in the units selected above:

InputValue
Macroscopic absorption cross-section at 2,200 m/s0.019700 1/cm
Thermal diffusion area8.1000 cm²
Geometric buckling (per cm²)0.003000 -
Slowing-down time (0 to ignore)10.000 µs

Applying the formula below gives:

ResultValue
Diffusion time in an infinite medium230.73 µs
Prompt neutron lifetime with leakage235.26 µs
Thermal non-leakage probability97.628 %

Open this example in the calculator and change any input.

Formula

\(t_d = \frac{1}{v_0\Sigma_{a,0}}, \quad \ell_p = \frac{t_d}{1 + L^2B^2} + t_s\)

Variables

Symbol Meaning SI unit
\(\Sigma_{a,0}\) Macroscopic absorption cross-section at 2,200 m/s 1/m
\(L^2\) Thermal diffusion area m²
\(B^2\) Geometric buckling (per cm²) -
\(t_s\) Slowing-down time (0 to ignore) s
\(t_d\) Diffusion time in an infinite medium s
\(\ell_p\) Prompt neutron lifetime with leakage s
\(P_{TNL}\) Thermal non-leakage probability -

Method and standards

Neutron lifetime.

Where it is used

  • Kinetics parameters for hand calculations.
  • Teaching reactor physics.

Common mistakes

  • Using the most probable speed with the 2,200 m/s cross-section inconsistently.
  • Ignoring leakage in small cores.

Assumptions and limits

  • 1/v absorption; one thermal group.

References

  • One-group neutron lifetime

Questions and answers

How long does a thermal neutron live in water?

About 0.2 ms; in graphite about 17 ms because carbon absorbs so little.

Why does it not depend on temperature?

Faster neutrons travel further but a 1/v absorber's cross-section falls in the same proportion, so the time to absorption is unchanged.

What do the defaults represent?

Illustrative ordinary water (Σ_a 0.0197 /cm, L² 8.1 cm²) in a core with B² 0.003 /cm² and 10 µs slowing-down time.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.