Worked example
Example: Illustrative bare sphere, k 1.12, M2 300 cm2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Core shape | Sphere |
| Infinite multiplication factor | 1.1200 - |
| Migration area | 300.00 cm² |
| Cylinder height-to-diameter ratio (0.924 gives the least volume) | 1.0000 - |
| Extrapolation distance (about 2.13 D) | 0 cm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Critical buckling (per cm²) | 4.0000e-04 |
| Critical radius (sphere, cylinder) or side (cube) | 157.08 cm |
| Critical volume | 16.235 m³ |
| Non-leakage probability 1/(1 + M²B²) | 89.286 % |
Open this example in the calculator and change any input.
Formula
\(B^2 = \frac{k_\infty - 1}{M^2}, \quad R_{sphere} = \frac{\pi}{B} - d, \quad B^2_{cyl} = \left(\frac{2.405}{\tilde R}\right)^2 + \left(\frac{\pi}{\tilde H}\right)^2\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{geometry}\) | Core shape | - |
| \(k_\infty\) | Infinite multiplication factor | - |
| \(M^2\) | Migration area | m² |
| \(H/D\) | Cylinder height-to-diameter ratio (0.924 gives the least volume) | - |
| \(d\) | Extrapolation distance (about 2.13 D) | m |
| \(B^2\) | Critical buckling (per cm²) | - |
| \(R\) | Critical radius (sphere, cylinder) or side (cube) | m |
| \(H\) | Critical height (cylinder) | m |
| \(V\) | Critical volume | m³ |
| \(P_{NL}\) | Non-leakage probability 1/(1 + M²B²) | - |
Method and standards
Modified one-group critical equation.
Where it is used
- Teaching and first estimates of core size.
- Criticality screening of simple shapes.
Common mistakes
- Using the diffusion length L² instead of the migration area M² = L² + τ.
- Forgetting the extrapolation distance in small cores.
Assumptions and limits
- Homogeneous bare core; one energy group.
References
- Modified one-group diffusion theory for bare reactors
Questions and answers
Why is the sphere the smallest critical shape?
It has the least surface for its volume, so the fewest neutrons leak out.
What H/D gives the smallest cylinder?
About 0.924 (minimum volume for a given buckling).
What do the defaults represent?
An illustrative bare sphere with k∞ 1.12 and a migration area of 300 cm².