Worked example
Example: Illustrative zero to full power. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fuel (Doppler) coefficient (pcm/K) | -2.5000 - |
| Fuel temperature change | 600.00 K |
| Moderator temperature coefficient (pcm/K) | -30.000 - |
| Moderator temperature change | 15.000 K |
| Void coefficient (pcm per % void) | -100.00 - |
| Void change (% points) | 0 - |
| Delayed neutron fraction | 0.65000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel feedback (pcm) | -1,500.0 |
| Moderator feedback (pcm) | -450.00 |
| Void feedback (pcm) | 0 |
| Total (pcm) | -1,950.0 |
| Total in dollars | -3.0000 |
Open this example in the calculator and change any input.
Formula
\(\Delta\rho = \alpha_f\Delta T_f + \alpha_m\Delta T_m + \alpha_v\Delta\alpha\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\alpha_f\) | Fuel (Doppler) coefficient (pcm/K) | - |
| \(\Delta T_f\) | Fuel temperature change | K |
| \(\alpha_m\) | Moderator temperature coefficient (pcm/K) | - |
| \(\Delta T_m\) | Moderator temperature change | K |
| \(\alpha_v\) | Void coefficient (pcm per % void) | - |
| \(\Delta\alpha\) | Void change (% points) | - |
| \(\beta\) | Delayed neutron fraction | - |
| \(\Delta\rho_f\) | Fuel feedback (pcm) | - |
| \(\Delta\rho_m\) | Moderator feedback (pcm) | - |
| \(\Delta\rho_v\) | Void feedback (pcm) | - |
| \(\Delta\rho\) | Total (pcm) | - |
| \(\Delta\rho/\beta\) | Total in dollars | - |
Method and standards
Reactivity feedback.
Where it is used
- Power manoeuvre planning and start-up physics.
- Operator training.
Common mistakes
- Mixing pcm with per cent Δk/k.
- Using beginning-of-cycle coefficients at end of cycle.
Assumptions and limits
- Constant coefficients; independent effects.
References
- Linear reactivity coefficients
Questions and answers
What is the power defect?
The reactivity lost going from zero to full power as fuel and moderator heat up; control rods or boron must make it up.
Why must the Doppler coefficient be negative?
It acts within milliseconds as the fuel heats, limiting any power excursion before slower controls respond.
What do the defaults represent?
An illustrative zero-to-full-power change: fuel +600 K at −2.5 pcm/K and moderator +15 K at −30 pcm/K, no void.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 7