Worked example
Example: Illustrative +100 pcm, 60 s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reactivity step (Δk/k) | 0.001000 - |
| Delayed neutron fraction | 0.65000 % |
| One-group decay constant of precursors | 0.076700 1/s |
| Prompt neutron generation time | 5.0000e-05 s |
| Time after the step | 60.000 s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stable period (exact one-group) | 71.767 s |
| Approximate period | 71.708 s |
| Prompt jump β/(β − ρ) | 1.1818 |
| Power ratio at time t | 2.7260 |
| Doubling time T ln 2 | 49.745 s |
| Reactivity in dollars | 0.15385 |
Open this example in the calculator and change any input.
Formula
\(\rho = \ell\omega + \frac{\beta\omega}{\omega + \lambda}, \quad \frac{P(t)}{P_0} = A_1e^{\omega_1 t} + A_2e^{\omega_2 t}, \quad T = \frac{1}{\omega_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho\) | Reactivity step (Δk/k) | - |
| \(\beta\) | Delayed neutron fraction | - |
| \(\lambda\) | One-group decay constant of precursors | 1/s |
| \(\ell\) | Prompt neutron generation time | s |
| \(t\) | Time after the step | s |
| \(T\) | Stable period (exact one-group) | s |
| \(T \approx (\beta - \rho)/(\lambda\rho)\) | Approximate period | s |
| \(P_+/P_0\) | Prompt jump β/(β − ρ) | - |
| \(P(t)/P_0\) | Power ratio at time t | - |
| \(T_2\) | Doubling time T ln 2 | s |
| \(\rho/\beta\) | Reactivity in dollars | - |
Method and standards
One-group point kinetics.
Where it is used
- Start-up rate and control rod worth checks.
- Reactor operator training.
Common mistakes
- Using the six-group β with a one-group λ chosen inconsistently.
- Applying the approximate period near prompt critical.
Assumptions and limits
- Point kinetics; no temperature feedback.
References
- Point reactor kinetics with one effective delayed-neutron group
Questions and answers
Why do delayed neutrons make reactors controllable?
Only 0.65 % of neutrons are delayed, but they lengthen the mean generation time from about 10⁻⁴ s to about 0.08 s, turning a millisecond period into tens of seconds.
What is the prompt jump?
Right after a step, power jumps quickly by β/(β − ρ) as prompt neutrons adjust, then rises on the stable period.
What do the defaults represent?
An illustrative +100 pcm step in a uranium-235 core: β 0.0065, λ 0.0767 /s and a generation time of 50 µs, 60 seconds after the step.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 7