Worked example
Example: Illustrative k 1.12, M2 300 cm2, 60 cm reflector. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Core infinite multiplication factor | 1.1200 - |
| Core migration area | 300.00 cm² |
| Core diffusion coefficient | 0.90000 cm |
| Reflector diffusion coefficient | 0.92000 cm |
| Reflector diffusion length | 54.000 cm |
| Reflector thickness | 60.000 cm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Material buckling (per cm²) | 4.0000e-04 |
| Bare critical radius | 157.08 cm |
| Reflector savings | 42.496 cm |
| Reflected critical radius | 114.58 cm |
| Core volume saved | 61.184 % |
Open this example in the calculator and change any input.
Formula
\(R_0 = \frac{\pi}{B}, \quad \delta = \frac{D_c}{D_r}L_r\tanh\frac{T}{L_r}, \quad R = R_0 - \delta\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k_\infty\) | Core infinite multiplication factor | - |
| \(M^2\) | Core migration area | m² |
| \(D_c\) | Core diffusion coefficient | m |
| \(D_r\) | Reflector diffusion coefficient | m |
| \(L_r\) | Reflector diffusion length | m |
| \(T\) | Reflector thickness | m |
| \(B^2\) | Material buckling (per cm²) | - |
| \(R_0\) | Bare critical radius | m |
| \(\delta\) | Reflector savings | m |
| \(R\) | Reflected critical radius | m |
| \(1 - (R/R_0)^3\) | Core volume saved | - |
Method and standards
Reflector savings.
Where it is used
- Core and research reactor sizing.
- Teaching reactor physics.
Common mistakes
- Using the reflector's own diffusion length for the core.
- Ignoring that the formula is one-group.
Assumptions and limits
- Spherical core; one group; homogeneous core and reflector.
References
- One-group reflector savings
Questions and answers
Why does a reflector shrink the core?
It returns leaking neutrons, so less fuel is needed to make up for leakage; the saving acts like an extra layer of core of thickness δ.
How thick should a reflector be?
About two diffusion lengths: beyond that tanh(T/L_r) is close to 1 and extra thickness adds little.
What do the defaults represent?
An illustrative core (k∞ 1.12, M² 300 cm², D 0.9 cm) with a 60 cm water-like reflector of D 0.92 cm and L 54 cm.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 6