FireCADCalc

Boron Dilution and Boration by Feed and Bleed

Time and water volume to dilute (or borate) the reactor coolant boron concentration by feed and bleed with perfect mixing, and the reactivity added.

Thermal power plant

Inputs

Examples: Illustrative dilution 1200 to 1100 ppm, 20 m3/hBoration 900 to 1500 ppm with 7000 ppmEnd-of-cycle dilution 50 to 10 ppm

Accepted: 0.1 to 5,000
Accepted: 0 to 5,000
Accepted: 1 to 1,000 m³
Accepted: 0.036 to 3,600 m³/h
Accepted: 100 to 50,000
Accepted: -30 to 0

Results

Well-mixed volume with equal feed and bleed: dilution with pure water gives C = C₁e^(−Qt/V); boration with feed C_b gives C_b − C = (C_b − C₁)e^(−Qt/V). Mixing delays and density differences are ignored; inadvertent dilution is a design-basis event.

Time to reach the target73.090min
Feed volume needed24.363m³
Reactivity change (pcm)900.00

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative dilution 1200 to 1100 ppm, 20 m3/h. The inputs, in the units selected above:

InputValue
Initial boron concentration (ppm)1,200.0 -
Target boron concentration (ppm)1,100.0 -
Coolant system volume280.00 m³
Feed (and bleed) rate20.000 m³/h
Boric acid feed concentration for boration (ppm)7,000.0 -
Boron worth (pcm per ppm, negative)-9.0000 -

Applying the formula below gives:

ResultValue
Time to reach the target73.090 min
Feed volume needed24.363 m³
Reactivity change (pcm)900.00

Open this example in the calculator and change any input.

Formula

\(t = \frac{V}{Q}\ln\frac{C_1}{C_2}\;\text{(dilution)}, \quad t = \frac{V}{Q}\ln\frac{C_b - C_1}{C_b - C_2}\;\text{(boration)}\)

Variables

Symbol Meaning SI unit
\(C_1\) Initial boron concentration (ppm) -
\(C_2\) Target boron concentration (ppm) -
\(V\) Coolant system volume m³
\(Q\) Feed (and bleed) rate m³/s
\(C_b\) Boric acid feed concentration for boration (ppm) -
\(\alpha_B\) Boron worth (pcm per ppm, negative) -
\(t\) Time to reach the target s
\(V_f\) Feed volume needed m³
\(\Delta\rho\) Reactivity change (pcm) -

Method and standards

Feed and bleed.

Where it is used

  • Load follow and cooldown boration planning.
  • Dilution event analysis.

Common mistakes

  • Using a linear rate for an exponential process.
  • Forgetting pressurizer and other volumes.

Assumptions and limits

  • Perfect mixing; equal feed and bleed rates.

References

  • Well-mixed tank feed and bleed balance

Questions and answers

Why does dilution slow down?

Each cubic metre of pure water removes boron in proportion to the current concentration, so the concentration falls exponentially.

How much reactivity is 100 ppm?

About 600–1,000 pcm at typical worths of −6 to −10 pcm/ppm.

What do the defaults represent?

An illustrative 280 m³ coolant system diluted from 1,200 to 1,100 ppm at 20 m³/h, with 7,000 ppm boric acid for boration and −9 pcm/ppm.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.