FireCADCalc

Neutron Radiation Weighting Factor and Equivalent Dose

Radiation weighting factor for neutrons of a given energy from the ICRP continuous function, and the equivalent dose from a neutron absorbed dose.

Thermal power plant

Inputs

Examples: Illustrative 1 MeV, 0.1 mGyThermal 0.025 eV, 1 mGy14 MeV fusion neutrons, 0.5 mGy

Accepted: 1E-9 to 10,000 MeV
Accepted: 0 to 10,000 mGy

Results

ICRP 103 continuous function of neutron energy (MeV); photons and electrons have w_R = 1, alphas 20. Equivalent dose H = w_R D for a single radiation type; sum over radiation types for mixed fields.

Radiation weighting factor20.692
Equivalent dose2.0692mSv

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1 MeV, 0.1 mGy. The inputs, in the units selected above:

InputValue
Neutron energy1.0000 MeV
Neutron absorbed dose0.10000 mGy

Applying the formula below gives:

ResultValue
Radiation weighting factor20.692
Equivalent dose2.0692 mSv

Open this example in the calculator and change any input.

Formula

\(w_R = 2.5 + 18.2e^{-[\ln E_n]^2/6}\;(E_n < 1\text{ MeV}), \quad 5.0 + 17.0e^{-[\ln(2E_n)]^2/6}\;(1\text{–}50\text{ MeV})\)

Variables

Symbol Meaning SI unit
\(E_n\) Neutron energy J
\(D\) Neutron absorbed dose Gy
\(w_R\) Radiation weighting factor -
\(H\) Equivalent dose Gy

Method and standards

Radiation weighting.

Where it is used

  • Neutron dosimetry and shielding assessments.
  • Radiation protection training.

Common mistakes

  • Using older step-function quality factors with ICRP 103 limits.
  • Applying w_R to effective dose without tissue factors.

Assumptions and limits

  • Single neutron energy; external exposure.

References

  • ICRP radiation weighting factor for neutrons

Questions and answers

Why do neutrons have a high weighting factor?

Their recoil protons deposit energy densely, causing more biological damage per gray than gamma rays; the factor peaks at about 20.7 near 1 MeV.

What about thermal neutrons?

About 2.5: slow neutrons cause damage mostly through capture gammas and low-energy protons.

What do the defaults represent?

An illustrative 1 MeV neutron field giving 0.1 mGy absorbed dose.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

ICRP Publication 103, The 2007 Recommendations of the International Commission on Radiological Protection (2007)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.