FireCADCalc

Pressure on the Bagasse Blanket (Hugot, Deerr)

Maximum pressure under the top roller from the load and delivery opening (Hugot eqn 10.67) and Deerr's pressure for a compression ratio (eqns 10.48–10.50).

Sugar mill and cogeneration

Inputs

Examples: 300 t on 1067 x 2134, 20 mmLighter compression

Results

Deerr's relation is for static compression of bagasse; the mill value (Jenkins) is higher because of the short time under load.

p_M comes from the load and opening, p_D and p_J from the compression ratio alone: they are separate estimates and are not cross-checked.

Jenkins' law gives 0 kg/cm² here. Hugot states the exponent-6 form for pressures of 50 kg/cm² and above (c up to about 0.11); below that p_J is outside its range.

Maximum pressure under the roller324.18kgf/cm²
Deerr static pressure for c (eqn 10.48)6.5055kgf/cm²
Deerr exponent at that pressure2.5929
Pressure in the mill for c (eqn 10.50)0.36045kgf/cm²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 300 t on 1067 x 2134, 20 mm. The inputs, in the units selected above:

InputValue
Load on the top roller (one opening)300.00 tf
Roller length2.1340 m
Roller diameter1.0670 m
Work opening20.000 mm
Compression ratio (compressed / initial volume)0.10000 -

Applying the formula below gives:

ResultValue
Maximum pressure under the roller288.70 kgf/cm²
Deerr static pressure for c (eqn 10.48)70.000 kgf/cm²
Deerr exponent at that pressure5.1159
Pressure in the mill for c (eqn 10.50)88.000 kgf/cm²

Open this example in the calculator and change any input.

Formula

\(p_M = \frac{3F}{L\sqrt{D\,e_A}}, \quad p_D = \frac{70}{(10c)^n},\ n = 6 - \frac{5800}{p_D^2 + 1660}, \quad p_J = \frac{88}{(10c)^6} \;[\mathrm{kg/cm^2}]\)

Variables

Symbol Meaning SI unit
\(F\) Load on the top roller (one opening) N
\(L\) Roller length m
\(D\) Roller diameter m
\(e_A\) Work opening m
\(c\) Compression ratio (compressed / initial volume) -
\(p_M\) Maximum pressure under the roller Pa
\(p_D\) Deerr static pressure for c (eqn 10.48) Pa
\(n\) Deerr exponent at that pressure -
\(p_J\) Pressure in the mill for c (eqn 10.50) Pa

Method and standards

Hugot's pressure distribution under the roller (eqn 10.67) and Deerr's and Jenkins' compression laws for bagasse (Hugot eqns 10.48–10.50, pp. 146–149). Deerr's law is fitted to his static tests (Table 10.2) and tabulated by Hugot for 1 to 1 000 kg/cm² (Table 10.3, c from 0.543 to 0.064). Hugot gives the exponent-6 form, used by Jenkins for mill conditions, for pressures of 50 kg/cm² and above.

Where it is used

  • Understanding mill pressures and settings.
  • Comparing static and mill compression.

Common mistakes

  • Using the total hydraulic load for one opening when it divides between feed and delivery.
  • Using percentages for c.

Assumptions and limits

  • Empirical compression laws for bagasse. A note appears when c is outside 0.064–0.543 (Deerr) or when p_J is below 50 kg/cm² (c above about 0.11), outside the ranges Hugot gives. The load-based p_M and the compression-based p_D and p_J are independent.
  • c is h/H (eqn 10.46); Hugot notes de Boer's objection that this is not the true compression in the mill (p. 150).
  • Deerr's implicit equation is solved after checking that it has a single root.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 10
  • eqns 10.48–10.50 (Deerr, Jenkins)
  • Tables 10.2–10.3
  • pp. 146–149
  • and eqn 10.67

Questions and answers

Why is the maximum pressure so much above the specific pressure?

The load acts on a narrow strip near the axial plane, not on the whole projected area.

What is the compression ratio c?

Compressed volume over the initial volume of the bagasse; 0.1 means squeezed to a tenth.

Why does Deerr's exponent vary?

Bagasse stiffens as it is squeezed: n rises from about 2.5 at low pressure towards 6.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.