Worked example
Example: 200 kW mill, individual drive. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean maximum power at the rollers | 200.00 kW |
| Gearing efficiency (motor to rollers) | 94.000 % |
| Drive efficiency (motor and converter) | 90.000 % |
| Margin over the mean maximum | 1.1500 - |
| Crushing rate | 100.00 t/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Motor shaft power | 212.77 kW |
| Motor rating | 244.68 kW |
| Electrical input | 236.41 kW |
| Electrical energy per tonne cane at the mean maximum load (upper bound) | 2.3641 kWh/t |
Open this example in the calculator and change any input.
Formula
\(P_m = \frac{P}{\rho}, \quad P_n = k\,P_m, \quad P_e = \frac{P_m}{\eta}, \quad E_c = \frac{P_e}{A}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Mean maximum power at the rollers | W |
| \(\rho\) | Gearing efficiency (motor to rollers) | - |
| \(\eta\) | Drive efficiency (motor and converter) | - |
| \(k\) | Margin over the mean maximum | - |
| \(A\) | Crushing rate | kg/s |
| \(P_m\) | Motor shaft power | W |
| \(P_n\) | Motor rating | W |
| \(P_e\) | Electrical input | W |
| \(E_c\) | Electrical energy per tonne cane | J/kg |
Method and standards
Power chain from rollers to the supply.
Where it is used
- Specifying mill motors and drives.
- Estimating mill electrical energy.
Common mistakes
- Sizing on the mean power instead of the mean maximum.
- Forgetting gearing losses.
Assumptions and limits
- Steady mean maximum load: the energy per tonne cane is therefore an upper bound, not the average consumption.
- The default gearing efficiency 0.94 is an assumed figure for an enclosed reducer; open pinions give about 0.78–0.79 (Hugot).
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 14 (installed power, p. 239) and ch. 15 (electric drives, pp. 241–248)
Questions and answers
Why 15 % above the mean maximum?
Hugot's rule for individual drives covers short overloads from thick blankets; combined drives share peaks and need 10 %.
Why does speed range matter?
Mills run at constant torque over a range of about 50–100 % of speed; the drive must deliver full torque at low speed.
What about turbines?
Compare steam by turbine and by electric drive with the mill turbine calculator.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.