FireCADCalc

Mill Delivery Opening from Fibre Loading (Hugot)

Working delivery opening from fibre loading and the density of compressed bagasse with re-absorption (Hugot eqns 10.15, 13.4–13.5), with the fibre index.

Sugar mill and cogeneration

Inputs

Examples: Hugot pp. 207-211: 300 TCH, first millLast mill

Murry: about 1.06 + 0.017 v (v in m/min) at compression 3; 1.1–1.4 usual.

Results

No-void volume of the bagasse0.82604L/kg
Density of compressed bagasse1,210.6kg/m³
Fibre index f′ d_B r786.89kg/m³
Fibre loading18.833kg/m²
Working delivery opening23.934mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot pp. 207-211: 300 TCH, first mill. The inputs, in the units selected above:

InputValue
Crushing rate300.00 t/h
Fibre % cane15.000 %
Roller speed6.0000 rpm
Roller diameter0.99000 m
Roller length2.1340 m
Fibre % of the bagasse leaving the mill33.000 %
Density of the juice in the mill1,040.0 kg/m³
Re-absorption factor1.3500 -

Applying the formula below gives:

ResultValue
No-void volume of the bagasse0.86457 L/kg
Density of compressed bagasse1,156.6 kg/m³
Fibre index f′ d_B r515.29 kg/m³
Fibre loading18.833 kg/m²
Working delivery opening36.550 mm

Open this example in the calculator and change any input.

Formula

\(V_0 = \frac{1}{d_J} - \left(\frac{1.20}{d_J} - 0.86\times10^{-3}\ \mathrm{m^3/kg}\right)f', \quad d_B = \frac{1}{V_0}, \quad \varphi = f' d_B r, \quad q = \frac{A f}{\pi D n L}, \quad e_A = \frac{q}{\varphi}\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(f\) Fibre % cane -
\(n\) Roller speed 1/s
\(D\) Roller diameter m
\(L\) Roller length m
\(f'\) Fibre % of the bagasse leaving the mill -
\(d_J\) Density of the juice in the mill kg/m³
\(r\) Re-absorption factor -
\(V_0\) No-void volume of the bagasse m³/kg
\(d_B\) Density of compressed bagasse kg/m³
\(\varphi\) Fibre index f′ d_B r kg/m³
\(q\) Fibre loading kg/m²
\(e_A\) Working delivery opening m

Method and standards

Hugot's no-void volume of bagasse (fibre density 1.52, fibraque 1.2 × fibre) and continuity through the delivery opening.

Where it is used

  • Setting delivery openings from first principles.
  • Checking settings for a new crush rate.

Common mistakes

  • Using fibre % cane instead of % bagasse for f′.
  • Ignoring re-absorption.

Assumptions and limits

  • V₀ in dm³/kg in Hugot's form, where the constant is 0.86 dm³/kg; here it is written in SI as 0.86 × 10⁻³ m³/kg with d_J in kg/m³.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 10
  • eqns 10.14–10.17
  • p. 136; ch. 13
  • eqns 13.4–13.5 and the example of pp. 207–211

Questions and answers

What is the no-void volume?

The volume of a kilogram of bagasse squeezed until no air is left: fibre, its water and the juice.

What is re-absorption?

The blanket swells as it leaves the nip and draws back juice; the opening must pass more volume than the compressed bagasse alone.

Which juice density?

The density of the juice in that mill, about 1 % above its density at atmospheric pressure (Hugot eqn 10.17).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.