FireCADCalc

Riser Size by Chvorinov's Rule (Modulus Method)

Solidification time of a casting by Chvorinov's rule and the diameter of a cylindrical riser whose modulus exceeds the casting's by your factor.

Inputs

Examples: 4 L castingHeavy block, tall riser

From trial castings in your sand and metal.

Results

The riser volume is 106 % of the casting volume: check that its feed metal (riser volume times its feeding efficiency) exceeds the casting's solidification shrinkage. The modulus rule alone does not check this.

Add insulating sleeves if used: they raise the riser's effective modulus.

Casting modulus V/A55.556mm
Casting solidification time B M²128.60min
Riser diameter355.56mm
Riser height533.33mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 4 L casting. The inputs, in the units selected above:

InputValue
Casting volume4.0000 L
Casting cooling surface area0.16000 m²
Mould constant (s/mm²)2.0000 -
Riser modulus / casting modulus1.2000 -
Riser height to diameter ratio1.0000 -

Applying the formula below gives:

ResultValue
Casting modulus V/A25.000 mm
Casting solidification time B M²20.833 min
Riser diameter180.00 mm
Riser height180.00 mm

Open this example in the calculator and change any input.

Formula

\(t_s = B\left(\frac{V}{A}\right)^2, \quad M_r = k M_c, \quad D_r = M_r\,\frac{2 + 4r}{r}\)

Variables

Symbol Meaning SI unit
\(V_c\) Casting volume m³
\(A_c\) Casting cooling surface area m²
\(B\) Mould constant (s/mm²) -
\(k\) Riser modulus / casting modulus -
\(H/D\) Riser height to diameter ratio -
\(M_c\) Casting modulus V/A m
\(t_s\) Casting solidification time B M² s
\(D_r\) Riser diameter m
\(H_r\) Riser height m

Method and standards

Chvorinov and modulus.

Where it is used

  • Foundry method design.
  • Examinations.

Common mistakes

  • Area including faces in contact with the riser.
  • Ignoring feed volume.

Assumptions and limits

  • Sand casting, simple shapes.
  • Side riser: the cylinder cools on its top, bottom and side (M = rD/(2 + 4r)). A top riser whose base sits on the casting, or one with an insulated top, has a larger modulus for the same size.
  • Feed volume is not checked: the note gives the riser volume as a share of the casting for that check.

References

  • Chvorinov (1940): t = B(V/A)²; riser modulus ≥ k × casting modulus
  • cylinder modulus rD/(2 + 4r) (Campbell; Kalpakjian)

Questions and answers

4 L casting with 0.16 m² surface?

Modulus 25 mm, solidification about 21 min; riser about 180 mm diameter and height (H/D 1, factor 1.2).

Why must the riser freeze last?

It feeds liquid metal into the shrinking casting.

Mould constant?

From trial castings in your sand and alloy.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators