Worked example
Example: Four 120 cm2 parts. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Projected area of one part | 120.00 cm² |
| Number of cavities | 4.0000 - |
| Projected area of the runner | 20.000 cm² |
| Mean cavity pressure (gauge) | 35.000 MPa |
| Safety margin | 15.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total projected area | 500.00 cm² |
| Clamping force | 2,012.5 kN |
| Clamping force in press units | 205.22 tf |
Open this example in the calculator and change any input.
Formula
\(F = (n A_p + A_r)\, p_c\, (1 + k)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A_p\) | Projected area of one part | m² |
| \(n\) | Number of cavities | - |
| \(A_r\) | Projected area of the runner | m² |
| \(p_c\) | Mean cavity pressure (gauge) | Pa |
| \(k\) | Safety margin | - |
| \(A\) | Total projected area | m² |
| \(F\) | Clamping force | N |
| \(P\) | Clamping force in press units | N |
Method and standards
Force balance.
Where it is used
- Machine selection.
- Tool quoting.
Common mistakes
- Part surface area instead of projected area.
- Forgetting the runner.
Assumptions and limits
- Uniform mean cavity pressure (gauge; the atmosphere acts on both sides of the mould).
- The press rating is shown in tonne-force (kip in FPS).
References
- F = projected area × cavity pressure × (1 + margin)
Questions and answers
Four 120 cm² parts and 20 cm² of runner at 35 MPa?
About 2012 kN: a 205 t machine.
Thin walls?
Long flows in thin walls need much higher pressure.
Flash?
Too little clamp lets the tool open: flash.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.