FireCADCalc

Fit Clearance or Interference from Hole and Shaft Limits

Maximum and minimum clearance or interference of a hole and shaft fit from their upper and lower limits, and the fit type (clearance, transition, interference).

Inputs

Examples: Running fitTransition fitInterference fit

Results

Take the limits from your drawing or ISO 286 table; the calculator does not hold the tables.

Maximum clearance H_max − S_min75.000µm
Minimum clearance H_min − S_max (negative: interference)25.000µm
Fit (1 clearance, 2 transition, 3 interference)1.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Running fit. The inputs, in the units selected above:

InputValue
Hole upper limit50.025 mm
Hole lower limit50.000 mm
Shaft upper limit49.975 mm
Shaft lower limit49.950 mm

Applying the formula below gives:

ResultValue
Maximum clearance H_max − S_min75.000 µm
Minimum clearance H_min − S_max (negative: interference)25.000 µm
Fit (1 clearance, 2 transition, 3 interference)1.0000

Open this example in the calculator and change any input.

Formula

\(C_{max} = H_{max} - S_{min}, \quad C_{min} = H_{min} - S_{max}\)

Variables

Symbol Meaning SI unit
\(H_{max}\) Hole upper limit m
\(H_{min}\) Hole lower limit m
\(S_{max}\) Shaft upper limit m
\(S_{min}\) Shaft lower limit m
\(C_{max}\) Maximum clearance H_max − S_min m
\(C_{min}\) Minimum clearance H_min − S_max (negative: interference) m
\(\text{type}\) Fit (1 clearance, 2 transition, 3 interference) -

Method and standards

Limits.

Where it is used

  • Bearing housings, couplings and bushes.
  • Drawing checks.

Common mistakes

  • Mixing deviations with limits.
  • Ignoring temperature differences.

Assumptions and limits

  • Measured at the same temperature.

References

  • Limits and fits: C_max = H_max − S_min
  • C_min = H_min − S_max (ISO 286 terminology)

Questions and answers

Ø50 H7 hole (+0/+25 µm) with an f7-like shaft (−25/−50 µm)?

Clearance 25 to 75 µm: a running fit.

Transition fit?

Minimum clearance negative and maximum positive: it may slide or need light pressing.

Interference?

Then use the interference fit calculator for the pressure.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators