Worked example
Example: M10 x 1.5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Measurement over wires | 10.311 mm |
| Pitch | 1.5000 mm |
| Wire diameter | 0.86600 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pitch diameter M + 0.86603P − 3W | 9.0120 mm |
| Best wire size 0.57735P | 0.86603 mm |
Open this example in the calculator and change any input.
Formula
\(E = M + 0.86603P - 3W, \quad W_b = 0.57735P\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M\) | Measurement over wires | m |
| \(P\) | Pitch | m |
| \(W\) | Wire diameter | m |
| \(E\) | Pitch diameter M + 0.86603P − 3W | m |
| \(W_b\) | Best wire size 0.57735P | m |
Method and standards
Thread geometry.
Where it is used
- Thread inspection.
- Gauge checks.
Common mistakes
- Wrong wire size.
- Not cleaning the threads.
Assumptions and limits
The wire must touch the thread flanks: usable diameters are about 0.505P to 1.01P for 60° threads, and the page warns outside that range. The best size 0.57735P touches at the pitch line.
60° symmetrical threads.
References
- E = M − 3W + 0.86603P for 60° threads; best wire 0.57735P (Machinery's Handbook)
Questions and answers
M10 × 1.5 over 0.866 mm wires reading 10.311 mm?
Pitch diameter 9.012 mm.
Why best wire size?
It touches the flanks at the pitch line, so flank angle errors matter least.
Other thread forms?
Acme and buttress need their own constants.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.