FireCADCalc

Straight Rectangular Fin: Heat Flow and Efficiency

Heat flow, fin efficiency and effectiveness of a straight rectangular fin with a convective tip, from thickness, length, conductivity and convection coefficient.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 2 mm aluminium, 30 mm, 100 mm wide, h 50, 60 KSteel 3 mm, 50 mm, h 30, 100 KCopper pin-like strip 1 mm, 20 mm, water h 1 000, 20 K

Results

One-dimensional fin with uniform h; m in 1/m. Effectiveness above about 2 justifies a fin.

Fin parameter √(hP/(kA_c))75.5931/m
Heat flow from the fin5.3152W
Fin efficiency59.058%
Fin effectiveness (vs no fin)26.576

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 mm aluminium, 30 mm, 100 mm wide, h 50, 60 K. The inputs, in the units selected above:

InputValue
Fin thickness2.0000 mm
Fin length (base to tip)30.000 mm
Fin width100.00 mm
Fin conductivity200.00 W/(m·K)
Convection coefficient50.000 W/(m²·K)
Base minus fluid temperature60.000 K

Applying the formula below gives:

ResultValue
Fin parameter √(hP/(kA_c))15.969 1/m
Heat flow from the fin17.551 W
Fin efficiency92.569 %
Fin effectiveness (vs no fin)29.252

Open this example in the calculator and change any input.

Formula

\(q_f = \sqrt{hPkA_c}\,\theta_b\,\frac{\sinh mL + (h/mk)\cosh mL}{\cosh mL + (h/mk)\sinh mL}, \quad m = \sqrt{\frac{hP}{kA_c}}\)

\(q_f = \sqrt{hPkA_c}\,\theta_b\,\frac{\tanh mL + h/(mk)}{1 + (h/mk)\tanh mL}, \quad \eta_f = \frac{q_f}{h A_f \theta_b}, \quad \varepsilon_f = \frac{q_f}{h A_c \theta_b}\)

\(A_c = w\,t, \quad P = 2(w + t), \quad A_f = PL + A_c\)

Variables

Symbol Meaning SI unit
\(t\) Fin thickness m
\(L\) Fin length (base to tip) m
\(w\) Fin width m
\(k\) Fin conductivity W/(m·K)
\(h\) Convection coefficient W/(m²·K)
\(\theta_b\) Base minus fluid temperature K
\(m\) Fin parameter √(hP/(kA_c)) 1/m
\(A_c\) Fin cross-section w t m²
\(P\) Fin perimeter 2(w + t) m
\(A_f\) Fin surface including the tip m²
\(q_f\) Heat flow from the fin W
\(\eta_f\) Fin efficiency -
\(\varepsilon_f\) Fin effectiveness (vs no fin) -

Method and standards

Fin equation with a convective tip.

Where it is used

  • Heat sinks and finned surfaces.
  • Heat transfer examinations.

Common mistakes

  • Ignoring the tip.
  • High h liquids where fins help little.

Assumptions and limits

  • Uniform h, steady state.
  • Efficiency and effectiveness do not depend on θ_b and are given also when θ_b = 0 (no heat flow). The tanh form of the solution is used, so long or thin fins do not overflow.

References

  • Incropera
  • DeWitt
  • Bergman and Lavine
  • Fundamentals of Heat and Mass Transfer
  • ch. 3 (fin with convective tip, Table 3.4)

Questions and answers

A 2 mm aluminium fin, 30 mm long, h 50, 60 K above air?

About 18 W per 100 mm width at roughly 93 % efficiency.

Why is aluminium preferred?

High conductivity keeps the fin tip close to base temperature.

When are fins worthwhile?

When h is low (gases): effectiveness well above 2.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.