FireCADCalc

Semi-Infinite Solid: Temperature after a Sudden Surface Change

Temperature at a depth below a surface suddenly held at a new temperature, and the penetration depth, for walls, soil and thick plates (semi-infinite solid).

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Steel at 20 °C, face to 100 °C, 20 mm, 10 minSoil 10 °C, surface −10 °C, 0.5 m, 30 daysRefractory 30 °C, hot face 900 °C, 50 mm, 1 h

k/(ρ c_p): steel about 12 mm²/s, concrete about 0.7, soil 0.3–0.8.

Results

Valid while the far side is not yet warmed: thickness well beyond the penetration depth.

Temperature at the depth418.73°C
Similarity variable x/(2√(α t))0.53791
Penetration depth 4√(α t)185.90mm
Surface heat flux at the time12.674kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steel at 20 °C, face to 100 °C, 20 mm, 10 min. The inputs, in the units selected above:

InputValue
Initial uniform temperature20.000 °C
Surface temperature held from time zero100.00 °C
Depth below the surface20.000 mm
Time600.00 s
Thermal diffusivity12.000 mm²/s
Conductivity (for the surface heat flux)45.000 W/(m·K)

Applying the formula below gives:

ResultValue
Temperature at the depth89.411 °C
Similarity variable x/(2√(α t))0.11785
Penetration depth 4√(α t)339.41 mm
Surface heat flux at the time23.937 kW/m²

Open this example in the calculator and change any input.

Formula

\(\frac{T(x,t) - T_s}{T_i - T_s} = \operatorname{erf}\frac{x}{2\sqrt{\alpha t}}, \quad q''_s = \frac{k (T_s - T_i)}{\sqrt{\pi\alpha t}}\)

Variables

Symbol Meaning SI unit
\(T_i\) Initial uniform temperature K
\(T_s\) Surface temperature held from time zero K
\(x\) Depth below the surface m
\(t\) Time s
\(\alpha\) Thermal diffusivity m²/s
\(k\) Conductivity (for the surface heat flux) W/(m·K)
\(T(x,t)\) Temperature at the depth K
\(\eta\) Similarity variable x/(2√(α t)) -
\(\delta_p\) Penetration depth 4√(α t) m
\(q''_s\) Surface heat flux at the time W/m²

Method and standards

Similarity solution of transient conduction.

Where it is used

  • Refractory warm-up, soil and frost depth.
  • Heat transfer examinations.

Common mistakes

  • Using it for thin walls.
  • Diffusivity in wrong units.

Assumptions and limits

  • Constant properties, constant surface temperature.

References

  • Incropera
  • DeWitt
  • Bergman and Lavine
  • Fundamentals of Heat and Mass Transfer
  • ch. 5 (semi-infinite solid, constant surface temperature)

Questions and answers

Steel suddenly at 100 °C on its face: temperature 20 mm in after 10 min?

About 89 °C with α 12 mm²/s.

What is the penetration depth?

4√(αt): beyond it the change is under 0.5 %.

Why does heat flux fall with time?

It goes as 1/√t as the heated layer thickens.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.