Worked example
Example: Hot casing 300 °C, 10 m², eps 0.8, room 30 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Arrangement | Small body in large surroundings |
| Surface area (of the body, or of one plate) | 10.000 m² |
| Hot surface temperature | 300.00 °C |
| Cold surface or surroundings temperature | 30.000 °C |
| Emissivity of the hot surface | 80.000 % |
| Emissivity of the cold plate (plates only) | 80.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Net heat exchange | 45.121 kW |
| Heat flux | 4.5121 kW/m² |
| Radiation heat transfer coefficient | 16.712 W/(m²·K) |
| Effective emissivity | 80.000 % |
Open this example in the calculator and change any input.
Formula
\(\dot Q = F_\varepsilon\,\sigma\,A\,(T_1^4 - T_2^4) \qquad F_\varepsilon = \varepsilon_1 \text{ (small body)} \quad F_\varepsilon = \frac{1}{1/\varepsilon_1 + 1/\varepsilon_2 - 1} \text{ (plates)} \qquad h_r = \frac{q}{T_1 - T_2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{case}\) | arrangement | – |
| \(A\) | area | m² |
| \(T_1\) | hot surface temperature | K |
| \(T_2\) | cold surface temperature | K |
| \(\varepsilon_1\) | hot emissivity | – |
| \(\varepsilon_2\) | cold emissivity | – |
| \(\dot Q\) | net heat exchange | W |
| \(q\) | heat flux | W/m² |
| \(h_r\) | radiation coefficient | W/(m²·K) |
| \(F_\varepsilon\) | effective emissivity | – |
| \(\sigma\) | Stefan–Boltzmann constant | W/(m²·K⁴) |
Method and standards
Stefan–Boltzmann law for grey diffuse surfaces in the two limiting geometries.
Where it is used
- Casing and duct heat loss.
- Furnace and heater wall checks.
- Personnel protection shields.
Common mistakes
- Using °C instead of K.
- Using emissivity of bright metal for oxidised surfaces.
- Ignoring absorbing flue gas between surfaces.
Assumptions and limits
- Grey, diffuse surfaces; non-absorbing medium.
References
- Stefan–Boltzmann law (CODATA 2018 σ)
Questions and answers
How much does a 10 m² casing at 300 °C radiate to a 30 °C room?
45.1 kW with emissivity 0.8 (4.5 kW/m², radiation coefficient 16.7 W/m²K).
Why use parallel plates?
For two large facing surfaces, such as a furnace wall and its casing, both emissivities count.
Does it include convection?
No; add convection separately or use the surface heat loss calculator.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.