Critical Heat Flux for a Fire-Tube Boiler Tube Bundle

Critical heat flux of a fire-tube boiler tube bundle: Mostinski pool value corrected by a bundle factor from bundle diameter, tube length and area.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Ganapathy Q8.47c: 590 tubes 2 in., 29.5 ft, 78 in. bundle, 400 psia (book F 0.15)Hydrogen plant WHB, 40 bar

Results

Vapour from the lower tubes blankets the upper ones, so a bundle reaches its limit at a fraction of the single-tube pool value; designers use 70–80 % of the bundle value (Ganapathy).

Bundle surface area646.35m²
Bundle factor D_bL/A0.014853
Bundle correction factor0.10665
Pool boiling critical heat flux (Mostinski)3,724.5kW/m²
Bundle critical heat flux397.23kW/m²
Allowable design flux278.06kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy Q8.47c: 590 tubes 2 in., 29.5 ft, 78 in. bundle, 400 psia (book F 0.15). The inputs, in the units selected above:

InputValue
Steam pressure (absolute)27.579 bar
Number of tubes590.00 -
Tube outside diameter50.800 mm
Tube length8.9916 m
Bundle diameter1,981.2 mm
Share of the corrected value allowed in design75.000 %

Applying the formula below gives:

ResultValue
Bundle surface area846.65 m²
Bundle factor D_bL/A0.021041
Bundle correction factor0.15077
Pool boiling critical heat flux (Mostinski)3,471.7 kW/m²
Bundle critical heat flux523.44 kW/m²
Allowable design flux392.58 kW/m²

Open this example in the calculator and change any input.

Formula

\(C = \frac{D_bL}{A}, \quad \log F = 0.8452 + 0.994\log C, \quad F \le 1, \quad q_{c,bundle} = F\,q_{c,pool}, \quad q_{c,pool} = 803\,p_c\left(\frac{p}{p_c}\right)^{0.35}\left(1 - \frac{p}{p_c}\right)^{0.9}\)

Variables

Symbol Meaning SI unit
\(p\) Steam pressure (absolute) Pa
\(N\) Number of tubes -
\(d_o\) Tube outside diameter m
\(L\) Tube length m
\(D_b\) Bundle diameter m
\(a\) Share of the corrected value allowed in design -
\(A\) Bundle surface area m²
\(C\) Bundle factor D_bL/A -
\(F\) Bundle correction factor -
\(q_{c,pool}\) Pool boiling critical heat flux (Mostinski) W/m²
\(q_{c,bundle}\) Bundle critical heat flux W/m²
\(q_{allow}\) Allowable design flux W/m²

Method and standards

Mostinski with Ganapathy's bundle factor.

Where it is used

  • Fire-tube waste heat boilers and kettle reboilers.
  • Hydrogen plant reformed-gas boilers.

Common mistakes

  • Comparing the average flux when the inlet flux is much higher.
  • Using the single-tube value for a bundle.

Assumptions and limits

  • Pool boiling of water outside horizontal tubes.
  • The bundle factor F is capped at 1.
  • US-unit correlation converted: p_c = 22.064 MPa = 3 200.1 psia, q in Btu/(ft²·h) × 3.154591 = W/m².

References

  • Ganapathy
  • Industrial Boilers and Heat Recovery Steam Generators (Marcel Dekker, 2003)
  • Q8.47b–c (Mostinski pool boiling CHF and the bundle correction log F = 0.8452 + 0.994 log C)

Questions and answers

What does Ganapathy's example give?

590 tubes of 2 in., 29.5 ft long in a 78 in. bundle: C = 0.021, F = 0.15, so the bundle limit is about 166,000 Btu/(ft²·h) (162,500 in the book, which starts from the Zuber value) against about 1.1 million for a single tube.

Is a fire-tube boiler near this limit?

Rarely with flue gas (20,000–30,000 Btu/(ft²·h)); reformed-gas boilers in hydrogen plants can approach it.

Why use 70–80 % of the value?

To allow for fouling, water quality and uneven flux at the tube inlets.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.