FireCADCalc

Heat Loss Through a Composite Wall (Three Layers)

Heat flux and interface temperatures through a plane wall of up to three layers with inside and outside surface coefficients, by thermal resistances in series.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Furnace wall: 230 mm firebrick, 115 mm insulating brick, 6 mm steelCold room: 150 mm PUF between steel skinsSingle 200 mm concrete wall

Layers (inside first)

Results

Conductivities at the mean temperature of each layer; check each interface against the layer's temperature limit.

Overall coefficient3.2483W/(m²·K)
Heat flux55.220W/m²
Inside surface temperature15.097°C
Interface 1–2 temperature7.2088°C
Interface 2–3 temperature7.2088°C
Outside surface temperature7.2088°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Furnace wall: 230 mm firebrick, 115 mm insulating brick, 6 mm steel. The inputs, in the units selected above:

InputValue
Inside fluid temperature900.00 °C
Outside fluid temperature30.000 °C
Inside surface coefficient50.000 W/(m²·K)
Outside surface coefficient (convection + radiation)10.000 W/(m²·K)
Layer 1 thickness230.00 mm
Layer 1 conductivity1.2000 W/(m·K)
Layer 2 thickness115.00 mm
Layer 2 conductivity0.25000 W/(m·K)
Layer 3 thickness6.0000 mm
Layer 3 conductivity45.000 W/(m·K)

Applying the formula below gives:

ResultValue
Overall coefficient1.2957 W/(m²·K)
Heat flux1,127.2 W/m²
Inside surface temperature877.46 °C
Interface 1–2 temperature661.40 °C
Interface 2–3 temperature142.87 °C
Outside surface temperature142.72 °C

Open this example in the calculator and change any input.

Formula

\(q'' = \frac{T_{in} - T_{out}}{\dfrac{1}{h_i} + \sum \dfrac{L_j}{k_j} + \dfrac{1}{h_o}}\)

Variables

Symbol Meaning SI unit
\(T_{in}\) Inside fluid temperature K
\(T_{out}\) Outside fluid temperature K
\(h_i\) Inside surface coefficient W/(m²·K)
\(h_o\) Outside surface coefficient (convection + radiation) W/(m²·K)
\(L_1\) Layer 1 thickness m
\(k_1\) Layer 1 conductivity W/(m·K)
\(L_2\) Layer 2 thickness m
\(k_2\) Layer 2 conductivity W/(m·K)
\(L_3\) Layer 3 thickness m
\(k_3\) Layer 3 conductivity W/(m·K)
\(U\) Overall coefficient W/(m²·K)
\(q''\) Heat flux W/m²
\(T_{s,i}\) Inside surface temperature K
\(T_{12}\) Interface 1–2 temperature K
\(T_{23}\) Interface 2–3 temperature K
\(T_{s,o}\) Outside surface temperature K

Method and standards

Steady one-dimensional conduction.

Where it is used

  • Furnaces, ovens and cold rooms.
  • Heat transfer examinations.

Common mistakes

  • Using room-temperature conductivities.
  • Ignoring contact resistance.

Assumptions and limits

  • Plane wall, steady state.
  • Constant conductivities: enter each at its layer's mean temperature and repeat if the interface temperatures move a lot (refractory conductivity varies strongly with temperature).
  • A fixed outside coefficient h_o including radiation: at hot surfaces radiation makes h_o depend on the surface temperature, so check h_o against the T_s,o found and repeat.

References

  • Fourier conduction with resistances in series (Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, ch. 3)

Questions and answers

Firebrick, insulating brick and steel at 900 °C inside?

U about 1.3 W/(m²·K), about 1.1 kW/m², steel shell near 143 °C.

Why check interface temperatures?

Insulating brick and fibre have upper limits; the hot face layer protects them.

What sets the outside coefficient?

Convection and radiation together, about 10 W/(m²·K) in still air.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.