Two-Phase Pressure Drop: Lockhart–Martinelli, Chisholm, Friedel, MSH

Two-phase frictional pressure gradient in a pipe by Lockhart–Martinelli, Chisholm's B-coefficient method, Friedel and Müller-Steinhagen–Heck correlations.

Thermal power plantRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Steam-water at 70 bar, x = 0.1, 50 mm tube (exchanger tubing fit)Air-water, high Y branch, 25 mm pipe, x = 0.02

Accepted: 0.36 to 3,600,000 kg/h
Accepted: 2 to 2,000 mm
Accepted: 0.1 to 99.9 %
Accepted: 50 to 2,000 kg/m³
Accepted: 0.01 to 500 kg/m³
Accepted: 0.001 to 1,000 mPa·s
Accepted: 1E-4 to 1 mPa·s
Accepted: 0.1 to 100 mN/m

Results

Separated-flow correlations; the Lockhart–Martinelli line uses X_tt and C = 20 (both phases turbulent). Friedel is valid for horizontal and vertical upflow; the MSH correlation is simplest and performed best in recent comparisons.

Total mass flux1,018.6kg/(m²·s)
Liquid-alone Reynolds number503,699
Liquid-alone pressure gradient157.80Pa/m
Lockhart–Martinelli parameter1.8780
Lockhart–Martinelli multiplier (C = 20)11.933
Lockhart–Martinelli gradient1,883.0Pa/m
Gradient for the total flow as liquid189.58Pa/m
Chisholm parameter3.6742
Chisholm coefficient1.7308
Chisholm multiplier3.8846
Chisholm gradient736.45Pa/m
Friedel multiplier4.0898
Friedel gradient775.35Pa/m
MSH multiplier3.3926
MSH gradient643.17Pa/m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steam-water at 70 bar, x = 0.1, 50 mm tube (exchanger tubing fit). The inputs, in the units selected above:

InputValue
Total mass flow7,200.0 kg/h
Pipe inside diameter50.000 mm
Vapour mass fraction (quality)10.000 %
Liquid density739.70 kg/m³
Vapour density36.500 kg/m³
Liquid viscosity0.091000 mPa·s
Vapour viscosity0.018900 mPa·s
Surface tension17.700 mN/m
Friction factor fitExchanger tubing: f = 0.4137 Re^−0.2585

Applying the formula below gives:

ResultValue
Total mass flux1,018.6 kg/(m²·s)
Liquid-alone Reynolds number503,699
Liquid-alone pressure gradient157.80 Pa/m
Lockhart–Martinelli parameter1.8780
Lockhart–Martinelli multiplier (C = 20)11.933
Lockhart–Martinelli gradient1,883.0 Pa/m
Gradient for the total flow as liquid189.58 Pa/m
Chisholm parameter3.6742
Chisholm coefficient1.7308
Chisholm multiplier3.8846
Chisholm gradient736.45 Pa/m
Friedel multiplier4.0898
Friedel gradient775.35 Pa/m
MSH multiplier3.3926
MSH gradient643.17 Pa/m

Open this example in the calculator and change any input.

Formula

\(\phi_L^2 = 1 + \frac{20}{X_{tt}} + \frac{1}{X_{tt}^2}, \quad \phi_{LO,Ch}^2 = 1 + (Y^2 - 1)\left\{B[x(1 - x)]^{(2 - n)/2} + x^{2 - n}\right\}\)

\(\phi_{LO,F}^2 = E + \frac{3.24FH}{Fr^{0.045}We^{0.035}}, \quad \phi_{LO,MSH}^2 = Y^2x^3 + [1 + 2x(Y^2 - 1)](1 - x)^{1/3}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Total mass flow kg/s
\(D_i\) Pipe inside diameter m
\(x\) Vapour mass fraction (quality) -
\(\rho_L\) Liquid density kg/m³
\(\rho_V\) Vapour density kg/m³
\(\mu_L\) Liquid viscosity Pa·s
\(\mu_V\) Vapour viscosity Pa·s
\(\sigma\) Surface tension N/m
\(f(Re)\) Friction factor fit -
\(G\) Total mass flux kg/(m²·s)
\(Re_L\) Liquid-alone Reynolds number -
\((\Delta P/L)_L\) Liquid-alone pressure gradient Pa/m
\(X_{tt}\) Lockhart–Martinelli parameter -
\(\phi_L^2\) Lockhart–Martinelli multiplier (C = 20) -
\((\Delta P/L)_{LM}\) Lockhart–Martinelli gradient Pa/m
\((\Delta P/L)_{LO}\) Gradient for the total flow as liquid Pa/m
\(Y\) Chisholm parameter -
\(B\) Chisholm coefficient -
\(\phi_{LO}^2\) Chisholm multiplier -
\((\Delta P/L)_{Ch}\) Chisholm gradient Pa/m
\(\phi_{LO,F}^2\) Friedel multiplier -
\((\Delta P/L)_{F}\) Friedel gradient Pa/m
\(\phi_{LO,MSH}^2\) MSH multiplier -
\((\Delta P/L)_{MSH}\) MSH gradient Pa/m

Method and standards

Separated-flow two-phase friction multipliers applied to single-phase gradients from a power-law friction factor.

Where it is used

  • Reboiler return lines and two-phase piping.
  • Condenser and evaporator tube pressure drop.

Common mistakes

  • Using the total flow in the liquid-alone gradient.
  • Applying X_tt when one phase is laminar.

Assumptions and limits

  • Adiabatic frictional gradient at a fixed quality; integrate along the pipe when the quality changes.

Questions and answers

Which correlation is most reliable?

Friedel is widely recommended; two later studies found the simpler Müller-Steinhagen–Heck method better. Lockhart–Martinelli usually predicts the highest losses.

Does this include static head and acceleration?

No: it is the friction gradient only. Add the gravitational term with a void fraction and the acceleration term where the quality changes.

What do the defaults represent?

An illustrative case: Steam-water at 70 bar, x = 0.1, 50 mm tube (exchanger tubing fit). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.4.2, eqs. 9.25 to 9.53 and Example 9.5 (Lockhart and Martinelli 1949; Chisholm 1967, 1973; Friedel 1979; Müller-Steinhagen and Heck 1986)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.