Worked example
Example: Water 50 m³/h in DN100 (102.3 mm). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Volume flow | 50.000 m³/h |
| Pipe inside diameter | 102.30 mm |
| Target velocity for sizing (0 = skip) | 0 m/s |
| Fluid density | 998.20 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Velocity | 1.6898 m/s |
| Flow area | 0.008219 m² |
| Mass flow | 49,910 kg/h |
| Velocity pressure ρv²/2 | 1,425.1 Pa |
Open this example in the calculator and change any input.
Formula
\(v = \frac{4Q}{\pi D^2} \qquad D_{req} = \sqrt{\frac{4Q}{\pi v_t}} \qquad \dot m = \rho\,Q \qquad p_d = \frac{\rho\,v^2}{2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | volume flow | m³/s |
| \(D\) | pipe inside diameter | m |
| \(v_t\) | target velocity for sizing | m/s |
| \(\rho\) | fluid density | kg/m³ |
| \(v\) | mean velocity | m/s |
| \(D_{req}\) | inside diameter for the target velocity | m |
| \(A\) | flow area | m² |
| \(\dot m\) | mass flow | kg/s |
| \(p_d\) | velocity pressure | Pa |
Method and standards
Continuity for a full circular pipe with a uniform mean velocity.
Where it is used
- Quick checks of line sizes for water, steam and air.
- Verifying velocity limits for erosion and noise.
- Choosing a size before a pressure-drop check.
Common mistakes
- Using nominal size instead of the actual bore of the schedule.
- Volume flow at the wrong pressure for gases and steam.
- Ignoring the velocity limits of the fluid and service.
Assumptions and limits
- Full pipe, single phase.
- The required diameter is exact; choose the next standard pipe size whose bore is at least that.
- For gases and steam use the volume flow at the line pressure and temperature.
References
- Continuity equation
Questions and answers
How do I find the velocity in a pipe?
v = 4Q/(πD²). 50 m³/h in a pipe of 102.3 mm bore flows at 1.69 m/s.
Which diameter do I enter?
The inside diameter: outside diameter minus twice the wall thickness. A DN100 schedule 40 pipe has a bore of 102.3 mm, not 100 mm.
What velocity should I design for?
The calculator does not suggest one. Use the limits of your company standard or project specification for the service; they depend on the fluid, erosion, noise and the pressure drop you can afford.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.