FireCADCalc

Normal Shock Wave Relations for a Perfect Gas

Downstream Mach number, pressure, temperature, density and stagnation-pressure loss across a normal shock in a perfect gas, with the pitot pressure.

Inputs

Examples: Illustrative: Mach 2 air at 50 kPa and 250 KWeak shock M 1.2 in air at 1 atm, 288 KStrong shock M 5 in helium (gamma 1.667)

Accepted: 1.0001 to 50
Accepted: 1.01 to 1.7
Accepted: 0.001 to 100,000 kPa
Accepted: 10 to 3,000 K

Results

Rankine–Hugoniot relations for a calorically perfect gas. A pitot tube in supersonic flow reads p₀₂, the stagnation pressure behind the bow shock (Rayleigh pitot formula).

Downstream Mach number0.47525
Downstream static pressure62.004kPa
Downstream temperature868.34K
Density ratio3.5703
Stagnation pressure ratio0.13976
Stagnation (pitot) pressure behind the shock74.345kPa
Entropy rise over the gas constant1.9679

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: Mach 2 air at 50 kPa and 250 K. The inputs, in the units selected above:

InputValue
Upstream Mach number2.0000 -
Ratio of specific heats1.4000 -
Upstream static pressure50.000 kPa
Upstream static temperature250.00 K

Applying the formula below gives:

ResultValue
Downstream Mach number0.57735
Downstream static pressure225.00 kPa
Downstream temperature421.87 K
Density ratio2.6667
Stagnation pressure ratio0.72087
Stagnation (pitot) pressure behind the shock282.02 kPa
Entropy rise over the gas constant0.32729

Open this example in the calculator and change any input.

Formula

\(M_2^2 = \frac{1 + \frac{\gamma - 1}{2}M_1^2}{\gamma M_1^2 - \frac{\gamma - 1}{2}}, \quad \frac{p_2}{p_1} = 1 + \frac{2\gamma}{\gamma + 1}(M_1^2 - 1), \quad \frac{\rho_2}{\rho_1} = \frac{(\gamma + 1)M_1^2}{2 + (\gamma - 1)M_1^2}\)

\(\frac{p_{02}}{p_{01}} = \left(\frac{\rho_2}{\rho_1}\right)^{\gamma/(\gamma - 1)}\left(\frac{\gamma + 1}{2\gamma M_1^2 - (\gamma - 1)}\right)^{1/(\gamma - 1)}\)

Variables

Symbol Meaning SI unit
\(M_1\) Upstream Mach number -
\(\gamma\) Ratio of specific heats -
\(p_1\) Upstream static pressure Pa
\(T_1\) Upstream static temperature K
\(M_2\) Downstream Mach number -
\(p_2\) Downstream static pressure Pa
\(T_2\) Downstream temperature K
\(\rho_2/\rho_1\) Density ratio -
\(p_{02}/p_{01}\) Stagnation pressure ratio -
\(p_{02}\) Stagnation (pitot) pressure behind the shock Pa
\(\Delta s/R\) Entropy rise over the gas constant -

Method and standards

Normal shock relations.

Where it is used

  • Supersonic inlets and diffusers, nozzles running off-design.
  • Pitot measurements in supersonic flow, shock tubes.

Common mistakes

  • Using the isentropic relations across a shock.
  • Reading a supersonic pitot pressure as the free-stream stagnation pressure.

Assumptions and limits

  • Calorically perfect gas, adiabatic, one-dimensional, steady.

References

  • Rankine–Hugoniot normal shock relations for a perfect gas

Questions and answers

Why does the stagnation pressure fall?

The shock is irreversible: entropy rises, and for the same stagnation temperature that means a lower stagnation pressure.

Can a shock make the flow supersonic?

No: a normal shock always takes supersonic flow to subsonic flow, never the reverse.

What do the defaults represent?

An illustrative Mach 2 air stream at 50 kPa and 250 K.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Anderson, Modern Compressible Flow, 3rd ed. (McGraw-Hill, 2003), ch. 3, NACA Report 1135, Equations, Tables and Charts for Compressible Flow (Ames Research Staff, 1953)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.