Worked example
Example: Illustrative: Mach 2 air at 50 kPa and 250 K. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Upstream Mach number | 2.0000 - |
| Ratio of specific heats | 1.4000 - |
| Upstream static pressure | 50.000 kPa |
| Upstream static temperature | 250.00 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Downstream Mach number | 0.57735 |
| Downstream static pressure | 225.00 kPa |
| Downstream temperature | 421.87 K |
| Density ratio | 2.6667 |
| Stagnation pressure ratio | 0.72087 |
| Stagnation (pitot) pressure behind the shock | 282.02 kPa |
| Entropy rise over the gas constant | 0.32729 |
Open this example in the calculator and change any input.
Formula
\(M_2^2 = \frac{1 + \frac{\gamma - 1}{2}M_1^2}{\gamma M_1^2 - \frac{\gamma - 1}{2}}, \quad \frac{p_2}{p_1} = 1 + \frac{2\gamma}{\gamma + 1}(M_1^2 - 1), \quad \frac{\rho_2}{\rho_1} = \frac{(\gamma + 1)M_1^2}{2 + (\gamma - 1)M_1^2}\)
\(\frac{p_{02}}{p_{01}} = \left(\frac{\rho_2}{\rho_1}\right)^{\gamma/(\gamma - 1)}\left(\frac{\gamma + 1}{2\gamma M_1^2 - (\gamma - 1)}\right)^{1/(\gamma - 1)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M_1\) | Upstream Mach number | - |
| \(\gamma\) | Ratio of specific heats | - |
| \(p_1\) | Upstream static pressure | Pa |
| \(T_1\) | Upstream static temperature | K |
| \(M_2\) | Downstream Mach number | - |
| \(p_2\) | Downstream static pressure | Pa |
| \(T_2\) | Downstream temperature | K |
| \(\rho_2/\rho_1\) | Density ratio | - |
| \(p_{02}/p_{01}\) | Stagnation pressure ratio | - |
| \(p_{02}\) | Stagnation (pitot) pressure behind the shock | Pa |
| \(\Delta s/R\) | Entropy rise over the gas constant | - |
Method and standards
Normal shock relations.
Where it is used
- Supersonic inlets and diffusers, nozzles running off-design.
- Pitot measurements in supersonic flow, shock tubes.
Common mistakes
- Using the isentropic relations across a shock.
- Reading a supersonic pitot pressure as the free-stream stagnation pressure.
Assumptions and limits
- Calorically perfect gas, adiabatic, one-dimensional, steady.
References
- Rankine–Hugoniot normal shock relations for a perfect gas
Questions and answers
Why does the stagnation pressure fall?
The shock is irreversible: entropy rises, and for the same stagnation temperature that means a lower stagnation pressure.
Can a shock make the flow supersonic?
No: a normal shock always takes supersonic flow to subsonic flow, never the reverse.
What do the defaults represent?
An illustrative Mach 2 air stream at 50 kPa and 250 K.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Anderson, Modern Compressible Flow, 3rd ed. (McGraw-Hill, 2003), ch. 3, NACA Report 1135, Equations, Tables and Charts for Compressible Flow (Ames Research Staff, 1953)