FireCADCalc

Flat-Plate Boundary Layer: Thickness and Skin-Friction Drag

Reynolds number, boundary layer thickness at the trailing edge, mean skin-friction coefficient and drag of a flat plate in laminar or turbulent flow.

Inputs

Examples: Illustrative 2 m plate in air at 10 m/sLaminar: 0.3 m plate in air at 5 m/sShip plating in water, 50 m at 8 m/s

Accepted: 0.0001 to 1,000 m/s
Accepted: 0.0001 to 1,000 m
Accepted: 0.0001 to 1,000 m
Accepted: 0.01 to 10,000 mm²/s
Accepted: 0.01 to 20,000 kg/m³
Accepted: 10,000 to 10,000,000

Results

Below the transition Reynolds number the Blasius similarity solution gives δ₉₉ = 4.91x/√Re_x and an average skin-friction coefficient 1.328/√Re_L. Above it the plate is taken as turbulent from the leading edge with Prandtl's one-seventh-power law, C_D = 0.074Re_L^−0.2 and δ = 0.37x·Re_x^−0.2, less a laminar-run correction A/Re_L with A = Re_cr(0.074Re_cr^−0.2 − 1.328/√Re_cr) (1,742 for Re_cr = 5 × 10⁵). Valid for smooth plates up to about Re = 10⁷; roughness, pressure gradients and free-stream turbulence move transition and raise drag.

Reynolds number at the trailing edge4.0000e+08
Transition position from the leading edge0.062500m
Boundary layer thickness at the trailing edge352.18mm
Average skin-friction coefficient0.001404
Drag on one side23,031N

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 2 m plate in air at 10 m/s. The inputs, in the units selected above:

InputValue
Free-stream velocity10.000 m/s
Plate length (in the flow direction)2.0000 m
Plate width1.0000 m
Kinematic viscosity15.000 mm²/s
Fluid density1.2000 kg/m³
Transition Reynolds number500,000 -

Applying the formula below gives:

ResultValue
Reynolds number at the trailing edge1,333,333
Transition position from the leading edge0.75000 m
Boundary layer thickness at the trailing edge44.080 mm
Average skin-friction coefficient0.003101
Drag on one side0.37214 N

Open this example in the calculator and change any input.

Formula

\(\delta = \frac{4.91x}{\sqrt{Re_x}}, \quad C_D = \frac{1.328}{\sqrt{Re_L}}; \quad C_D = \frac{0.074}{Re_L^{0.2}} - \frac{A}{Re_L}\)

Variables

Symbol Meaning SI unit
\(U\) Free-stream velocity m/s
\(L\) Plate length (in the flow direction) m
\(b\) Plate width m
\(\nu\) Kinematic viscosity m²/s
\(\rho\) Fluid density kg/m³
\(Re_{cr}\) Transition Reynolds number -
\(Re_L\) Reynolds number at the trailing edge -
\(x_{tr}\) Transition position from the leading edge m
\(\delta_L\) Boundary layer thickness at the trailing edge m
\(C_D\) Average skin-friction coefficient -
\(F_D\) Drag on one side N

Method and standards

Boundary layer.

Where it is used

  • Skin-friction drag of hulls, fins, panels and ducts.
  • Estimating boundary layer thickness for sensor placement.

Common mistakes

  • Using laminar results at high Reynolds numbers.
  • Counting both sides when one is wanted.

Assumptions and limits

  • Smooth flat plate; zero pressure gradient; incompressible flow.

References

  • Blasius and one-seventh-power flat-plate results

Questions and answers

Why does turbulent flow give more drag?

Turbulent mixing brings fast fluid close to the wall, steepening the velocity gradient and the wall shear.

What transition Reynolds number should I use?

About 5 × 10⁵ for a smooth plate in a quiet stream; lower with roughness or free-stream turbulence.

What do the defaults represent?

An illustrative 2 × 1 m plate in air at 10 m/s.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Schlichting and Gersten, Boundary-Layer Theory, 9th ed. (Springer, 2017)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.