FireCADCalc

Reverse Osmosis Flux and Salt Passage (Solution–Diffusion)

Water flux, permeate concentration and salt rejection of a reverse osmosis membrane from permeabilities A and B, pressure and osmotic pressures.

Thermal power plantDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Brackish 2 g/L NaCl at 15 barSea water 35 g/L at 60 bar

Results

Concentration at the membrane surface is above the bulk because of polarisation (often 10–20 % in spiral elements). Osmotic pressure by van 't Hoff, adequate below about 35 g/L of NaCl.

Feed osmotic pressure29.693bar
Water flux (L/(m²·h))30.356
Permeate concentration57.555mg/L
Salt rejection99.836%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Brackish 2 g/L NaCl at 15 bar. The inputs, in the units selected above:

InputValue
Water permeability (L/(m²·h·bar))3.0000 -
Salt permeability (L/(m²·h))0.15000 -
Applied transmembrane pressure15.000 bar
Feed-side salt concentration at the membrane2.0000 g/L
van 't Hoff factor2.0000 -
Salt molar mass58.440 kg/kmol
Temperature25.000 °C

Applying the formula below gives:

ResultValue
Feed osmotic pressure1.6968 bar
Water flux (L/(m²·h))39.929
Permeate concentration7.4853 mg/L
Salt rejection99.626 %

Open this example in the calculator and change any input.

Formula

\(J_w = A(\Delta p - \Delta\pi), \quad J_s = B(C_f - C_p), \quad C_p = \frac{BC_f}{J_w + B}, \quad \pi = \frac{iC}{M}RT\)

Variables

Symbol Meaning SI unit
\(A\) Water permeability (L/(m²·h·bar)) -
\(B\) Salt permeability (L/(m²·h)) -
\(\Delta p\) Applied transmembrane pressure Pa
\(C_f\) Feed-side salt concentration at the membrane kg/m³
\(i\) van 't Hoff factor -
\(M\) Salt molar mass kg/kmol
\(T\) Temperature K
\(\pi_f\) Feed osmotic pressure Pa
\(J_w\) Water flux (L/(m²·h)) -
\(C_p\) Permeate concentration kg/m³
\(R\) Salt rejection -

Method and standards

Solution–diffusion model.

Where it is used

  • RO design checks.
  • Effect of temperature and feed salinity.

Common mistakes

  • Using bulk instead of wall concentration.
  • Ignoring temperature correction of A.

Assumptions and limits

  • Dilute solutions; van 't Hoff osmotic pressure, adequate below about 35 g/L; above that it is flagged as an extrapolation.
  • A, B and J_w are plain numbers in L/(m²·h·bar) and L/(m²·h) in every unit system: 1 L/(m²·h) = 0.589 gal/(ft²·d) (GFD), and 1 L/(m²·h·bar) = 0.0406 GFD/psi.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 20 (reverse osmosis: J_w = A(Δp − Δπ), J_s = BΔC)
  • van 't Hoff osmotic pressure

Questions and answers

Why does flux fall as feed gets saltier?

Water only flows against the osmotic pressure difference; brackish water needs 10–20 bar, sea water 55–70 bar.

Why does rejection rise with pressure?

Water flux grows with pressure while salt flux does not, so the permeate is diluted more.

What do the defaults represent?

A brackish-water element at 15 bar with 2 g/L NaCl.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.