FireCADCalc

Plug-Flow and Batch Reactor Conversion (1st and 2nd Order)

Conversion in a plug-flow or batch reactor for first- and second-order kinetics from rate constant and time, with the CSTR time for the same conversion.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: First order, k 0.002/s, 20 minSecond order, k 1e-6 m3/(mol s), 1000 mol/m3First order, k 0.12 per min, 20 minSecond order, k 0.06 L/(mol h), 1000 mol/m3

A plain number in the units chosen in 'Units of k'. First order: per s, min or h; second order: m³ or L per mol per s, min or h.

Results

Conversion64.286%
CSTR residence time for the same conversion84.000min
CSTR / PFR volume ratio2.8000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: First order, k 0.002/s, 20 min. The inputs, in the units selected above:

InputValue
Reaction orderFirst order
Rate constant, in the units chosen below0.002000 -
Units of k1/s or m³/(mol·s)
Residence (or batch) time20.000 min
Initial concentration (2nd order)1.0000 mol/L

Applying the formula below gives:

ResultValue
Conversion90.928 %
CSTR residence time for the same conversion83.526 min
CSTR / PFR volume ratio4.1763

Open this example in the calculator and change any input.

Formula

\(X_1 = 1 - e^{-k\tau}, \quad X_2 = \frac{k\tau C_0}{1 + k\tau C_0}, \quad \tau_{CSTR,1} = \frac{X}{k(1 - X)}, \quad \tau_{CSTR,2} = \frac{X}{kC_0(1 - X)^2}\)

Variables

Symbol Meaning SI unit
\(\text{order}\) Reaction order -
\(k\) Rate constant, in the units chosen below -
\(\text{units of }k\) Units of k (per s, min or h; m³ or L per mol) -
\(\tau\) Residence (or batch) time s
\(C_0\) Initial concentration (2nd order) mol/m³
\(X\) Conversion -
\(\tau_{CSTR}\) CSTR residence time for the same conversion s
\(\tau_{CSTR}/\tau\) CSTR / PFR volume ratio -

Method and standards

Ideal reactor design equations (isothermal, constant density).

Where it is used

  • Reactor sizing.
  • Comparing reactor types.

Common mistakes

  • Mixing rate constant units.
  • Using for non-isothermal reactors.

Assumptions and limits

  • Isothermal; constant density; irreversible.
  • k is converted to SI from the units chosen (1/s or m³/(mol·s)); a textbook value of 0.12 1/min must be entered with the per-minute units, not as 0.12 1/s.
  • At complete conversion the CSTR time is infinite and is not shown; with no residence time the volume ratio is not shown.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 7 and 19 (reaction kinetics and reactor design): ideal plug-flow and stirred-tank reactors

Questions and answers

Why is a batch reactor the same as a PFR?

Each slug of fluid in a PFR behaves like a small batch reactor for the residence time.

Why does a CSTR need more volume?

It runs at the outlet concentration, the lowest rate, throughout.

What units does k take for 2nd order?

m³/(mol·s) with C₀ in mol/m³, so k τ C₀ is dimensionless.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.