Worked example
Example: First order, k 0.002/s, 20 min. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reaction order | First order |
| Rate constant, in the units chosen below | 0.002000 - |
| Units of k | 1/s or m³/(mol·s) |
| Residence (or batch) time | 20.000 min |
| Initial concentration (2nd order) | 1.0000 mol/L |
Applying the formula below gives:
| Result | Value |
|---|---|
| Conversion | 90.928 % |
| CSTR residence time for the same conversion | 83.526 min |
| CSTR / PFR volume ratio | 4.1763 |
Open this example in the calculator and change any input.
Formula
\(X_1 = 1 - e^{-k\tau}, \quad X_2 = \frac{k\tau C_0}{1 + k\tau C_0}, \quad \tau_{CSTR,1} = \frac{X}{k(1 - X)}, \quad \tau_{CSTR,2} = \frac{X}{kC_0(1 - X)^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{order}\) | Reaction order | - |
| \(k\) | Rate constant, in the units chosen below | - |
| \(\text{units of }k\) | Units of k (per s, min or h; m³ or L per mol) | - |
| \(\tau\) | Residence (or batch) time | s |
| \(C_0\) | Initial concentration (2nd order) | mol/m³ |
| \(X\) | Conversion | - |
| \(\tau_{CSTR}\) | CSTR residence time for the same conversion | s |
| \(\tau_{CSTR}/\tau\) | CSTR / PFR volume ratio | - |
Method and standards
Ideal reactor design equations (isothermal, constant density).
Where it is used
- Reactor sizing.
- Comparing reactor types.
Common mistakes
- Mixing rate constant units.
- Using for non-isothermal reactors.
Assumptions and limits
- Isothermal; constant density; irreversible.
- k is converted to SI from the units chosen (1/s or m³/(mol·s)); a textbook value of 0.12 1/min must be entered with the per-minute units, not as 0.12 1/s.
- At complete conversion the CSTR time is infinite and is not shown; with no residence time the volume ratio is not shown.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 7 and 19 (reaction kinetics and reactor design): ideal plug-flow and stirred-tank reactors
Questions and answers
Why is a batch reactor the same as a PFR?
Each slug of fluid in a PFR behaves like a small batch reactor for the residence time.
Why does a CSTR need more volume?
It runs at the outlet concentration, the lowest rate, throughout.
What units does k take for 2nd order?
m³/(mol·s) with C₀ in mol/m³, so k τ C₀ is dimensionless.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.