FireCADCalc

Press Section Dryness: Water to Evaporate per Tonne

Water carried into the dryers per tonne of paper at the press-section exit dryness and final dryness, and the evaporation saved by one point more press dryness.

Pulp and paper

Inputs

Examples: 45 % to 92 %, 1000 t/dShoe press 52 %

Results

Here one more point of press dryness cuts the water to evaporate by 4.3 %; dryer steam falls roughly in proportion. Pressing water out is far cheaper than drying it.

Water evaporated per tonne of paper1.0444kg/kg
Evaporation43.519t/h
Saving per +1 point of press dryness4.2553%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 45 % to 92 %, 1000 t/d. The inputs, in the units selected above:

InputValue
Dryness after the press section45.000 %
Dryness at the reel92.000 %
Paper production (at reel dryness)1,000.0 t/d

Applying the formula below gives:

ResultValue
Water evaporated per tonne of paper1.0444 kg/kg
Evaporation43.519 t/h
Saving per +1 point of press dryness4.2553 %

Open this example in the calculator and change any input.

Formula

\(E = \frac{d_{reel}}{d_{press}} - 1, \quad \dot E = E\,P, \quad \Delta E = \frac{E - E(d_{press} + 0.01)}{E}\)

Variables

Symbol Meaning SI unit
\(d_{press}\) Dryness after the press section -
\(d_{reel}\) Dryness at the reel -
\(P\) Paper production (at reel dryness) kg/s
\(E\) Water evaporated per tonne of paper kg/kg
\(\dot E\) Evaporation kg/s
\(\Delta E\) Saving per +1 point of press dryness -

Method and standards

Water balance per tonne of paper at reel dryness.

Where it is used

  • Press section upgrades.
  • Dryer steam budgets.

Common mistakes

  • Using moisture instead of dryness.
  • Per tonne of OD fibre vs per tonne of paper.

Assumptions and limits

  • No water added between press and reel.
  • ΔE is the saving in water evaporated; dryer steam falls roughly in proportion.

References

  • Smook
  • Handbook for Pulp & Paper Technologists
  • 3rd ed. (Angus Wilde, 2002)
  • ch. 16.9 and 17 (pressing and drying; dryness definitions)

Questions and answers

How much water is evaporated?

At 45 % press dryness and 92 % reel dryness, about 1.04 t per tonne of paper.

Why does a point matter so much?

Evaporation falls by about 4–5 % per point of press dryness.

What raises press dryness?

Shoe presses, steam boxes and hotter sheets.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.