Tensile index in N·m/g, burst index in kPa·m²/g, tear index in mN·m²/g.

Tensile index, N·m/g80.000
Burst index, kPa·m²/g4.3333
Tear index, mN·m²/g13.333
Breaking length8.1577km

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 80 g/m2 copy paper. The inputs, in the units selected above:

InputValue
Grammage80.000 g/m²
Tensile strength (force per width)5.5000 kN/m
Burst pressure250.00 kPa
Tearing resistance0.65000 N

Applying the formula below gives:

ResultValue
Tensile index, N·m/g68.750
Burst index, kPa·m²/g3.1250
Tear index, mN·m²/g8.1250
Breaking length7.0105 km

Open this example in the calculator and change any input.

Formula

\(TI = \frac{T\ [\mathrm{N/m}]}{G\ [\mathrm{g/m^2}]}, \quad BI = \frac{p_b\ [\mathrm{kPa}]}{G\ [\mathrm{g/m^2}]}, \quad TrI = \frac{F_t\ [\mathrm{mN}]}{G\ [\mathrm{g/m^2}]}, \quad BL = \frac{T}{Gg}\)

Variables

Symbol Meaning SI unit
\(G\) Grammage kg/m²
\(T\) Tensile strength (force per width) N/m
\(p_b\) Burst pressure Pa
\(F_t\) Tearing resistance N
\(TI\) Tensile index, N·m/g -
\(BI\) Burst index, kPa·m²/g -
\(TrI\) Tear index, mN·m²/g -
\(BL\) Breaking length m

Method and standards

Index definitions.

Where it is used

  • Pulp evaluation and refining trials.

Common mistakes

  • Mixing MD and CD values.
  • Using g/m² with kN/m without conversion.

Assumptions and limits

  • Conditioned samples (23 °C, 50 % RH).
  • The indices use T in N/m, p_b in kPa, F_t in mN and G in g/m², giving N·m/g, kPa·m²/g and mN·m²/g; breaking length is in SI.

References

  • Smook
  • Handbook for Pulp & Paper Technologists
  • 3rd ed. (Angus Wilde, 2002)
  • ch. 22 (strength properties and indices)

Questions and answers

Why divide by grammage?

Heavier sheets are stronger simply because they hold more fibre; indices compare fibre quality.

What is breaking length?

The length of a strip that would break under its own weight: tensile index / g.

What units are used?

N·m/g for tensile, kPa·m²/g for burst and mN·m²/g for tear.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.