Worked example
Example: 1200 / 1224 / 1236 / 1242 m/min. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wire speed | 1,200.0 m/min |
| Press section speed | 1,224.0 m/min |
| Dryer section speed | 1,236.0 m/min |
| Reel speed | 1,242.0 m/min |
Applying the formula below gives:
| Result | Value |
|---|---|
| Draw wire → press | 2.0000 % |
| Draw press → dryers | 0.98039 % |
| Draw dryers → reel | 0.48544 % |
| Total draw wire → reel | 3.5000 % |
Open this example in the calculator and change any input.
Formula
\(d = \frac{v_{i+1}}{v_i} - 1, \quad d_t = \frac{v_r}{v_w} - 1\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(v_w\) | Wire speed | m/s |
| \(v_p\) | Press section speed | m/s |
| \(v_d\) | Dryer section speed | m/s |
| \(v_r\) | Reel speed | m/s |
| \(d_{wp}\) | Draw wire → press | - |
| \(d_{pd}\) | Draw press → dryers | - |
| \(d_{dr}\) | Draw dryers → reel | - |
| \(d_t\) | Total draw wire → reel | - |
Method and standards
Draw definitions.
Where it is used
- Machine tuning.
- Break analysis.
Common mistakes
- Comparing draws at different speeds without %.
- Reading drive speeds instead of sheet speeds.
Assumptions and limits
- Steady running.
- A negative draw (a section slower than the one before) is flagged.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 16–17 (sheet transfer and draws between sections)
- Definitions and mass and energy balances
Questions and answers
Why is there a draw?
Wet paper stretches; each section runs slightly faster to keep the sheet taut.
What draws are usual?
1–3 % at the first press open draw, smaller later.
Why does the reel run fastest?
The sheet keeps stretching and the reel must hold tension.