FireCADCalc

Dryer Section Steam per Tonne of Paper

Dryer section steam use per tonne of paper and per hour from press and reel dryness, paper production and the steam used per kg of water evaporated.

Pulp and paper

Inputs

Examples: 45 % to 92 %, 1.3 kg/kgTissue Yankee

Typical 1.3–1.6 kg/kg.

Results

Water evaporated per tonne1.3750kg/kg
Steam per tonne of paper1.9937kg/kg
Steam to the dryers16.615t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 45 % to 92 %, 1.3 kg/kg. The inputs, in the units selected above:

InputValue
Dryness entering the dryers45.000 %
Dryness at the reel92.000 %
Paper production1,000.0 t/d
Steam per kg of water evaporated1.3000 kg/kg

Applying the formula below gives:

ResultValue
Water evaporated per tonne1.0444 kg/kg
Steam per tonne of paper1.3578 kg/kg
Steam to the dryers56.574 t/h

Open this example in the calculator and change any input.

Formula

\(E = \frac{d_{reel}}{d_{press}} - 1, \quad S = sE\)

Variables

Symbol Meaning SI unit
\(d_{press}\) Dryness entering the dryers -
\(d_{reel}\) Dryness at the reel -
\(P\) Paper production kg/s
\(s\) Steam per kg of water evaporated kg/kg
\(E\) Water evaporated per tonne kg/kg
\(S\) Steam per tonne of paper kg/kg
\(\dot S\) Steam to the dryers kg/s

Method and standards

Water balance with a specific steam consumption.

Where it is used

  • Steam budgets and audits.

Common mistakes

  • Ignoring steam to steam boxes and hood air heating.

Assumptions and limits

  • s includes all dryer losses.

References

  • Smook
  • Handbook for Pulp & Paper Technologists
  • 3rd ed. (Angus Wilde, 2002)
  • ch. 17 (drying: steam-heated cylinders; steam per unit water evaporated)

Questions and answers

Why more than 1 kg of steam per kg of water?

Latent heat of steam roughly equals that of the evaporated water, plus sheet heating, hood air and losses.

What is typical?

1.3–1.6 t of steam per tonne of water evaporated; about 1.5–2.5 t per tonne of paper.

What improves it?

Higher press dryness, good condensate removal and a closed, humid hood.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.