Xenon-135 Poisoning: Equilibrium Worth and Post-Shutdown Peak

Equilibrium xenon-135 reactivity worth at a given thermal flux and the xenon build-up after shutdown, with the time and size of the xenon peak.

Thermal power plant

Inputs

Examples: Illustrative 3e13 n/cm2 s, 8 h after shutdownHigh flux 1e14, 24 hLow flux 2e12, 5 h (small peak)

Accepted: 1E+10 to 1E+16 1/(cm²·s)
Accepted: 2 to 3.2
Accepted: 0 to 10 %
Accepted: 0 to 10 %
Accepted: 10,000 to 100,000,000 b
Accepted: 1 to 277.78 h
Accepted: 1 to 277.78 h
Accepted: 0 to 2,777.8 h

Results

One-group equilibrium worth ρ∞ = −(γ_I + γ_X)/ν · φ/(φ + φ_X), assuming the fuel absorbs all thermal neutrons that are not lost to xenon (f ≈ 1); real cores worth about 2.5–3 %. After shutdown iodine keeps decaying to xenon while burn-out stops, so xenon peaks some hours later; reactivity at t is scaled with the concentration.

Characteristic flux λ_X/σ_X7.9493e+121/(cm²·s)
Equilibrium xenon reactivity-0.005482
Equilibrium xenon reactivity (pcm)-548.21
Xenon relative to equilibrium at t0.97550
Approximate xenon reactivity at t (pcm)-534.78
Time of the xenon peak1.6649h
Peak xenon relative to equilibrium1.0124

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 3e13 n/cm2 s, 8 h after shutdown. The inputs, in the units selected above:

InputValue
Thermal neutron flux at power3.0000e+13 1/(cm²·s)
Neutrons per fission2.4300 -
Iodine-135 fission yield6.3900 %
Direct xenon-135 fission yield0.23700 %
Xenon-135 absorption cross-section2,650,000 b
Iodine-135 half-life6.5700 h
Xenon-135 half-life9.1400 h
Time after shutdown8.0000 h

Applying the formula below gives:

ResultValue
Characteristic flux λ_X/σ_X7.9493e+12 1/(cm²·s)
Equilibrium xenon reactivity-0.021559
Equilibrium xenon reactivity (pcm)-2,155.9
Xenon relative to equilibrium at t1.9004
Approximate xenon reactivity at t (pcm)-4,097.1
Time of the xenon peak8.3797 h
Peak xenon relative to equilibrium1.9015

Open this example in the calculator and change any input.

Formula

\(\rho_\infty = -\frac{\gamma_I + \gamma_X}{\nu}\frac{\phi_T}{\phi_T + \phi_X}, \quad \frac{X(t)}{X_\infty} = e^{-\lambda_X t} + \frac{\gamma_I(\lambda_X + \sigma_X\phi_T)}{(\gamma_I + \gamma_X)(\lambda_X - \lambda_I)}\left(e^{-\lambda_I t} - e^{-\lambda_X t}\right)\)

Variables

Symbol Meaning SI unit
\(\phi_T\) Thermal neutron flux at power 1/(m²·s)
\(\nu\) Neutrons per fission -
\(\gamma_I\) Iodine-135 fission yield -
\(\gamma_X\) Direct xenon-135 fission yield -
\(\sigma_X\) Xenon-135 absorption cross-section m²
\(T_I\) Iodine-135 half-life s
\(T_X\) Xenon-135 half-life s
\(t\) Time after shutdown s
\(\phi_X\) Characteristic flux λ_X/σ_X 1/(m²·s)
\(\rho_\infty\) Equilibrium xenon reactivity -
\(X(t)/X_\infty\) Xenon relative to equilibrium at t -
\(\rho(t)\) Approximate xenon reactivity at t (pcm) -
\(t_{max}\) Time of the xenon peak s
\(X_{max}/X_\infty\) Peak xenon relative to equilibrium -

Method and standards

Iodine-xenon one-group balance.

Where it is used

  • Restart planning after trips.
  • Load-follow and xenon oscillation awareness.

Common mistakes

  • Ignoring the post-shutdown peak when planning a restart.
  • Using the 2,200 m/s cross-section for a hot spectrum without averaging.

Assumptions and limits

  • Uniform flux; samarium and spatial xenon oscillations are not included.

References

  • Iodine-xenon balance equations (one group)

Questions and answers

Why can a reactor not restart some hours after a trip?

Xenon from iodine decay peaks 6–11 hours after shutdown; its negative reactivity can exceed what the control system has in reserve (the 'iodine pit').

Why is there a characteristic flux?

Below φ_X = λ_X/σ_X (about 8 × 10¹² n/cm²·s) xenon is removed mainly by decay; above it, mainly by burning, so the worth saturates.

What do the defaults represent?

An illustrative uranium-235 core at a thermal flux of 3 × 10¹³ n/cm²·s, 8 hours after shutdown.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.