Worked example
Example: Illustrative 3e13 n/cm2 s, 8 h after shutdown. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Thermal neutron flux at power | 3.0000e+13 1/(cm²·s) |
| Neutrons per fission | 2.4300 - |
| Iodine-135 fission yield | 6.3900 % |
| Direct xenon-135 fission yield | 0.23700 % |
| Xenon-135 absorption cross-section | 2,650,000 b |
| Iodine-135 half-life | 6.5700 h |
| Xenon-135 half-life | 9.1400 h |
| Time after shutdown | 8.0000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Characteristic flux λ_X/σ_X | 7.9493e+12 1/(cm²·s) |
| Equilibrium xenon reactivity | -0.021559 |
| Equilibrium xenon reactivity (pcm) | -2,155.9 |
| Xenon relative to equilibrium at t | 1.9004 |
| Approximate xenon reactivity at t (pcm) | -4,097.1 |
| Time of the xenon peak | 8.3797 h |
| Peak xenon relative to equilibrium | 1.9015 |
Open this example in the calculator and change any input.
Formula
\(\rho_\infty = -\frac{\gamma_I + \gamma_X}{\nu}\frac{\phi_T}{\phi_T + \phi_X}, \quad \frac{X(t)}{X_\infty} = e^{-\lambda_X t} + \frac{\gamma_I(\lambda_X + \sigma_X\phi_T)}{(\gamma_I + \gamma_X)(\lambda_X - \lambda_I)}\left(e^{-\lambda_I t} - e^{-\lambda_X t}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\phi_T\) | Thermal neutron flux at power | 1/(m²·s) |
| \(\nu\) | Neutrons per fission | - |
| \(\gamma_I\) | Iodine-135 fission yield | - |
| \(\gamma_X\) | Direct xenon-135 fission yield | - |
| \(\sigma_X\) | Xenon-135 absorption cross-section | m² |
| \(T_I\) | Iodine-135 half-life | s |
| \(T_X\) | Xenon-135 half-life | s |
| \(t\) | Time after shutdown | s |
| \(\phi_X\) | Characteristic flux λ_X/σ_X | 1/(m²·s) |
| \(\rho_\infty\) | Equilibrium xenon reactivity | - |
| \(X(t)/X_\infty\) | Xenon relative to equilibrium at t | - |
| \(\rho(t)\) | Approximate xenon reactivity at t (pcm) | - |
| \(t_{max}\) | Time of the xenon peak | s |
| \(X_{max}/X_\infty\) | Peak xenon relative to equilibrium | - |
Method and standards
Iodine-xenon one-group balance.
Where it is used
- Restart planning after trips.
- Load-follow and xenon oscillation awareness.
Common mistakes
- Ignoring the post-shutdown peak when planning a restart.
- Using the 2,200 m/s cross-section for a hot spectrum without averaging.
Assumptions and limits
- Uniform flux; samarium and spatial xenon oscillations are not included.
References
- Iodine-xenon balance equations (one group)
Questions and answers
Why can a reactor not restart some hours after a trip?
Xenon from iodine decay peaks 6–11 hours after shutdown; its negative reactivity can exceed what the control system has in reserve (the 'iodine pit').
Why is there a characteristic flux?
Below φ_X = λ_X/σ_X (about 8 × 10¹² n/cm²·s) xenon is removed mainly by decay; above it, mainly by burning, so the worth saturates.
What do the defaults represent?
An illustrative uranium-235 core at a thermal flux of 3 × 10¹³ n/cm²·s, 8 hours after shutdown.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 7