FireCADCalc

Spent Fuel Pool Heat-Up, Time to Boil and Boil-Off

Time for a spent fuel pool to reach boiling after loss of cooling, the boil-off rate, level fall and the time until the water falls to the top of the fuel.

Thermal power plant

Inputs

Examples: Illustrative 108 m2 pool, 5 MW, 40 CFull-core offload 12 MW, 30 COld inventory 1 MW, 35 C, 140 m2

Accepted: 0.001 to 1,000 MW
Accepted: 1 to 10,000 m²
Accepted: 0.5 to 30 m
Accepted: 0 to 30 m
Accepted: 0.85 to 98.85 °C
Accepted: 50 to 200 kPa
Accepted: 0 to 80 %

Results

Adiabatic pool: heat-up t_b = m_w(h_f − h₀)/Q, then boil-off ṁ = Q/h_fg. Heat losses from the surface and walls, which lengthen the times, are ignored (conservative); the racked fuel zone holds less water than the open pool above it. Water and steam properties from IAPWS-IF97.

Water mass1,156.0t
Time to boil7.8443h
Boil-off rate19,144kg/h
Level fall while boiling0.18496m/h
Time from boiling until the water reaches the top of the fuel37.846h
Total time to uncover the fuel45.690h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 108 m2 pool, 5 MW, 40 C. The inputs, in the units selected above:

InputValue
Decay heat in the pool5.0000 MW
Pool water surface area108.00 m²
Total water depth12.000 m
Water depth above the top of the fuel7.0000 m
Initial pool temperature40.000 °C
Pressure at the pool surface101.33 kPa
Fraction of the pool volume taken by racks and fuel20.000 %

Applying the formula below gives:

ResultValue
Water mass1,178.8 t
Time to boil16.461 h
Boil-off rate7,976.8 kg/h
Level fall while boiling0.077067 m/h
Time from boiling until the water reaches the top of the fuel90.829 h
Total time to uncover the fuel107.29 h

Open this example in the calculator and change any input.

Formula

\(t_b = \frac{m_w(h_f - h_0)}{Q}, \quad \dot m_b = \frac{Q}{h_{fg}}, \quad t_u = \frac{H_a\rho_fA}{\dot m_b}\)

Variables

Symbol Meaning SI unit
\(Q\) Decay heat in the pool W
\(A\) Pool water surface area m²
\(H\) Total water depth m
\(H_a\) Water depth above the top of the fuel m
\(T_0\) Initial pool temperature K
\(p\) Pressure at the pool surface Pa
\(\phi\) Fraction of the pool volume taken by racks and fuel -
\(m_w\) Water mass kg
\(t_b\) Time to boil s
\(\dot m_b\) Boil-off rate kg/s
\(\dot z\) Level fall while boiling m/s
\(t_u\) Time from boiling until the water reaches the top of the fuel s
\(t_b + t_u\) Total time to uncover the fuel s

Method and standards

Pool energy balance.

Where it is used

  • Loss-of-cooling response planning.
  • Outage planning for full-core offloads.

Common mistakes

  • Using the full-power decay heat long after shutdown.
  • Ignoring the racks' displacement of water.

Assumptions and limits

  • Adiabatic and well mixed; no make-up or heat loss.

References

  • Adiabatic heat-up and boil-off energy balance

Questions and answers

How long does a pool take to boil?

Typically from several hours just after a full-core offload to days for an old inventory; this sets the time available to restore cooling.

What boil-off does 1 MW give?

About 1.6 t of water per hour (h_fg about 2,257 kJ/kg at atmospheric pressure).

What do the defaults represent?

An illustrative pool of 108 m² with 12 m of water (7 m above the fuel, racks taking 20 % of the lower 5 m), 5 MW of decay heat and water at 40 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.