FireCADCalc

Evaporation Rate from a Liquid Pool and Ventilation Dilution

Evaporation rate of a volatile liquid from an open pool or tank by the mass-transfer method, and the vapour concentration with dilution ventilation.

Process steam and utilitiesDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Crowl and Louvar Example 3-8: toluene, 5 ft tankAcetone spill, 2 m² equivalent, k 0.3

Results

Still air over the pool, liquid at a uniform temperature, low vapour pressure against ambient. The non-ideal mixing factor k is 0.1–0.5 (0.1 for poor mixing). Wind raises the evaporation rate.

A screening estimate for training and early design, not a hazard or risk study.

Gas-phase mass transfer coefficient0.004816m/s
Evaporation rate4.4192kg/h
Vapour concentration in the room (ppm by volume)2,302.1

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Crowl and Louvar Example 3-8: toluene, 5 ft tank. The inputs, in the units selected above:

InputValue
Molar mass of the liquid92.140 kg/kmol
Vapour pressure at the liquid temperature3.7597 kPa
Liquid temperature25.000 °C
Pool or liquid surface area1.8241 m²
Ventilation rate3,000.0 ft³/min
Non-ideal mixing factor (0.1–0.5)0.10000 -
Ambient pressure101.33 kPa

Applying the formula below gives:

ResultValue
Gas-phase mass transfer coefficient0.004816 m/s
Evaporation rate4.4196 kg/h
Vapour concentration in the room (ppm by volume)2,302.3

Open this example in the calculator and change any input.

Formula

\(K = K_0\left(\frac{M_0}{M}\right)^{1/3},\ K_0 = 0.83\ \text{cm/s},\ M_0 = 18, \quad Q_m = \frac{MKAP^{sat}}{R_gT_L}, \quad C_{ppm} = \frac{Q_mR_gT}{kQ_vPM}\times10^6\)

Variables

Symbol Meaning SI unit
\(M\) Molar mass of the liquid kg/kmol
\(P^{sat}\) Vapour pressure at the liquid temperature Pa
\(T_L\) Liquid temperature K
\(A\) Pool or liquid surface area m²
\(Q_v\) Ventilation rate m³/s
\(k\) Non-ideal mixing factor (0.1–0.5) -
\(P\) Ambient pressure Pa
\(K\) Gas-phase mass transfer coefficient m/s
\(Q_m\) Evaporation rate kg/s
\(C_{ppm}\) Vapour concentration in the room (ppm by volume) -

Method and standards

Mass transfer from the liquid surface into still air, with dilution ventilation.

Where it is used

  • Open tanks, drums and spills indoors.
  • Ventilation design for solvent handling.

Common mistakes

  • Using it for boiling liquids.
  • Ignoring wind outdoors.

Assumptions and limits

  • Low vapour pressure; still air.

References

  • Crowl and Louvar
  • Chemical Process Safety: Fundamentals with Applications
  • 2nd ed. (Prentice Hall, 2002)
  • ch. 3
  • eqs. 3-12 to 3-18
  • Example 3-8

Questions and answers

Why use water as the reference?

Its mass transfer coefficient over a pool in still air is well known (0.83 cm/s); other liquids scale with (18/M)^(1/3).

What is k?

A factor for imperfect mixing in the room: the real concentration near the source is higher than the well-mixed value, so k < 1.

What do the defaults represent?

Crowl and Louvar's Example 3-8: toluene at 25 °C from a 5 ft (1.52 m) tank, 3,000 ft³/min ventilation, k = 0.1.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.