Worked example
Example: Propane at 100 °C and 2 MPa. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Carbon atoms in the fuel molecule | 3.0000 - |
| Hydrogen atoms | 8.0000 - |
| Oxygen atoms | 0 - |
| Net heat of combustion (for the temperature effect) | 2,043.5 kJ/mol |
| Temperature | 100.00 °C |
| Pressure (absolute) | 2,000.0 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stoichiometric fuel concentration in air | 4.0217 % |
| Lower flammability limit at 25 °C, 1 atm | 2.2119 % |
| Upper flammability limit at 25 °C, 1 atm | 14.076 % |
| LFL at temperature T | 2.0968 % |
| UFL at temperature T | 14.191 % |
| UFL at pressure P (25 °C) | 40.877 % |
Open this example in the calculator and change any input.
Formula
\(C_{st} = \frac{100}{1 + 4.773z},\ z = m + \frac{x}{4} - \frac{y}{2}, \quad LFL = 0.55C_{st}, \quad UFL = 3.50C_{st}\)
\(LFL_T = LFL_{25} - \frac{0.75}{\Delta H_c}(T - 25), \quad UFL_T = UFL_{25} + \frac{0.75}{\Delta H_c}(T - 25), \quad UFL_P = UFL + 20.6(\log P + 1)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m\) | Carbon atoms in the fuel molecule | - |
| \(x\) | Hydrogen atoms | - |
| \(y\) | Oxygen atoms | - |
| \(\Delta H_c\) | Net heat of combustion (for the temperature effect) | J/mol |
| \(T\) | Temperature | K |
| \(P\) | Pressure (absolute) | Pa |
| \(C_{st}\) | Stoichiometric fuel concentration in air | - |
| \(LFL\) | Lower flammability limit at 25 °C, 1 atm | - |
| \(UFL\) | Upper flammability limit at 25 °C, 1 atm | - |
| \(LFL_T\) | LFL at temperature T | - |
| \(UFL_T\) | UFL at temperature T | - |
| \(UFL_P\) | UFL at pressure P (25 °C) | - |
Method and standards
Jones' correlation with the stoichiometric concentration; temperature effect from Zabetakis (ΔH_c in kcal/mol, T in °C, limits in volume %); UFL with pressure in MPa absolute.
Where it is used
- Inerting and purge design.
- Area classification inputs and safe operating windows.
Common mistakes
- Using gross heat of combustion.
- Applying the pressure formula to the LFL.
Assumptions and limits
- Hydrocarbon vapours; approximate.
References
- Crowl and Louvar
- Chemical Process Safety: Fundamentals with Applications
- 2nd ed. (Prentice Hall, 2002)
- ch. 6
- eqs. 6-4 to 6-11 (Jones; Zabetakis)
Questions and answers
Why does the range widen with temperature?
A warmer mixture needs less heat from the reaction to keep a flame going, so leaner and richer mixtures burn.
Does pressure change the LFL?
Very little above about 50 mmHg; the UFL rises markedly with pressure.
What do the defaults represent?
Propane (C₃H₈, ΔH_c 2,043.5 kJ/mol) at 100 °C, and its upper limit at 20 bar.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.