Worked example
Example: 1.5 MJ/kg reactant at 30 %, 10 g sample in 8 g cell. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat of reaction (released, per kg of reactant) | 1,500.0 kJ/kg |
| Mass fraction of reactant in the mixture | 30.000 % |
| Specific heat of the mixture | 2.5000 kJ/(kg·K) |
| Starting temperature | 60.000 °C |
| Sample mass in the test cell | 0.010000 kg |
| Test cell mass | 0.008000 kg |
| Test cell specific heat | 0.46000 kJ/(kg·K) |
| Temperature rise measured in the test | 120.00 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Adiabatic temperature rise | 180.00 K |
| Maximum temperature after full conversion | 240.00 °C |
| Phi factor of the test | 1.1472 |
| Test result corrected to plant scale | 137.66 K |
Open this example in the calculator and change any input.
Formula
\(\Delta T_{ad} = \frac{(-\Delta H_r)x}{C_p}, \quad T_{max} = T_0 + \Delta T_{ad}, \quad \phi = 1 + \frac{m_cC_{p,c}}{m_sC_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(-\Delta H_r\) | Heat of reaction (released, per kg of reactant) | J/kg |
| \(x\) | Mass fraction of reactant in the mixture | - |
| \(C_p\) | Specific heat of the mixture | J/(kg·K) |
| \(T_0\) | Starting temperature | K |
| \(m_s\) | Sample mass in the test cell | kg |
| \(m_c\) | Test cell mass | kg |
| \(C_{p,c}\) | Test cell specific heat | J/(kg·K) |
| \(\Delta T_{meas}\) | Temperature rise measured in the test | K |
| \(\Delta T_{ad}\) | Adiabatic temperature rise | K |
| \(T_{max}\) | Maximum temperature after full conversion | K |
| \(\phi\) | Phi factor of the test | - |
| \(\phi\Delta T_{meas}\) | Test result corrected to plant scale | K |
Method and standards
Adiabatic heat balance and the phi factor.
Where it is used
- Batch reactor safety reviews.
- Interpreting ARC and ARSST results.
Common mistakes
- Using a measured rise without the phi correction.
- Ignoring secondary decompositions.
Assumptions and limits
- Adiabatic; full conversion.
References
- Crowl and Louvar
- Chemical Process Safety: Fundamentals with Applications
- 2nd ed. (Prentice Hall, 2002)
- ch. 8
- eq. 8-1 (phi factor) and adiabatic heat balance
Questions and answers
What is the phi factor?
The ratio of the total heat capacity of sample plus test cell to that of the sample; part of the reaction heat warms the cell, so the measured rise is too low by this factor.
Why does it matter?
The maximum temperature decides whether solvent boils, gases form or a secondary decomposition starts.
What do the defaults represent?
A reaction releasing 1.5 MJ per kg of reactant at 30 % in the mixture, starting at 60 °C, with a 10 g sample in an 8 g steel cell.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.