Worked example
Example: 1 t hydrocarbon at 5 %, 100 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mass of flammable material in the cloud | 1,000.0 kg |
| Heat of combustion (energy of explosion) | 46,000 kJ/kg |
| Explosion efficiency (1–10 % for vapour clouds) | 5.0000 % |
| Distance from the explosion centre | 100.00 m |
| Ambient pressure | 101.33 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Equivalent mass of TNT | 490.82 kg |
| Scaled distance r/m_TNT^(1/3) | 12.677 |
| Peak side-on overpressure | 14.804 kPa |
| Scaled overpressure | 0.14611 |
Open this example in the calculator and change any input.
Formula
\(m_{TNT} = \frac{\eta\,m\,\Delta H_c}{E_{TNT}},\ E_{TNT} = 4686\ \text{kJ/kg}, \quad z_e = \frac{r}{m_{TNT}^{1/3}}\)
\(\frac{p^o}{p_a} = \frac{1616\left[1 + \left(\frac{z_e}{4.5}\right)^2\right]}{\sqrt{\left[1 + \left(\frac{z_e}{0.048}\right)^2\right]\left[1 + \left(\frac{z_e}{0.32}\right)^2\right]\left[1 + \left(\frac{z_e}{1.35}\right)^2\right]}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m\) | Mass of flammable material in the cloud | kg |
| \(\Delta H_c\) | Heat of combustion (energy of explosion) | J/kg |
| \(\eta\) | Explosion efficiency (1–10 % for vapour clouds) | - |
| \(r\) | Distance from the explosion centre | m |
| \(p_a\) | Ambient pressure | Pa |
| \(m_{TNT}\) | Equivalent mass of TNT | kg |
| \(z_e\) | Scaled distance r/m_TNT^(1/3) | - |
| \(p^o\) | Peak side-on overpressure | Pa |
| \(p^o/p_a\) | Scaled overpressure | - |
Method and standards
TNT equivalence with the Kinney–Graham fit of the TNT overpressure curve (z_e in m/kg^(1/3)).
Where it is used
- Siting of control rooms and occupied buildings (screening).
- Training on explosion consequences.
Common mistakes
- Using 100 % efficiency for vapour clouds.
- Applying it close to a congested area without a congestion-based method.
Assumptions and limits
- Hemispherical free-field blast; ideal TNT curve.
References
- Crowl and Louvar
- Chemical Process Safety: Fundamentals with Applications
- 2nd ed. (Prentice Hall, 2002)
- ch. 6
- eqs. 6-25
- 6-27 and 6-28 (Kinney and Graham)
Questions and answers
What explosion efficiency should I use?
Usually 1–10 % for vapour clouds, reflecting incomplete mixing and the low conversion of combustion energy into blast; 100 % for condensed explosives.
What overpressure breaks windows?
Around 1–2 kPa; light structures fail at about 7–14 kPa and reinforced buildings near 70 kPa.
What do the defaults represent?
1 t of hydrocarbon (46 MJ/kg) at 5 % efficiency, 100 m from the centre.