Worked example
Example: Hydrocarbon 1 pS/m, to 1 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Relative permittivity | 2.0000 - |
| Electrical conductivity (pS/m) | 1.0000 - |
| Fraction of charge remaining | 1.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Relaxation time constant | 17.708 s |
| Time to fall to the fraction | 81.550 s |
| 1 = low-conductivity (≤ 50 pS/m) accumulator | 1.0000 |
Open this example in the calculator and change any input.
Formula
\(\tau = \frac{\varepsilon_r\varepsilon_0}{\kappa}, \quad t_f = \tau\ln\frac1f\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\varepsilon_r\) | Relative permittivity | - |
| \(\kappa\) | Electrical conductivity (pS/m) | - |
| \(f\) | Fraction of charge remaining | - |
| \(\tau\) | Relaxation time constant | s |
| \(t_f\) | Time to fall to the fraction | s |
| \(\text{class}\) | 1 = low-conductivity (≤ 50 pS/m) accumulator | - |
Method and standards
Ohmic charge relaxation.
Where it is used
- Tank filling and solvent handling.
Common mistakes
- Using conductivity in µS/cm without converting (1 µS/cm = 10⁸ pS/m).
Assumptions and limits
- Ohmic relaxation; hyperbolic relaxation at very low conductivity is slower.
References
- Charge relaxation τ = ε_r ε₀/κ (electrostatics; Perry's sec. 23 on static electricity)
Questions and answers
Why does conductivity matter?
Charge leaks away through the liquid; poorly conducting liquids keep it long enough to spark.
What is a static accumulator?
A liquid below about 50 pS/m, such as toluene, diesel or hexane.
How can relaxation be helped?
Antistatic additives raise conductivity; relaxation tanks give time before the liquid reaches a tank.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.