Worked example
Example: 21,400 Pa (Crowl and Louvar Example 2-5), 12.5 kW/m² for 30 s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Peak overpressure | 21.400 kPa |
| Thermal radiation intensity | 12.500 kW/m² |
| Exposure time to the radiation | 30.000 s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Deaths from lung haemorrhage | 0 % |
| Eardrum rupture | 8.7599 % |
| Structural damage | 62.390 % |
| Glass breakage | 100.000 % |
| Burn deaths from flash or pool fire | 0.50588 % |
| Burn probit | 2.4282 |
Open this example in the calculator and change any input.
Formula
\(Y = k_1 + k_2\ln V, \quad P = 50\left[1 + \frac{Y - 5}{|Y - 5|}\operatorname{erf}\frac{|Y - 5|}{\sqrt2}\right]\)
\(V = p^o\ (\text{lung: } -77.1, 6.91;\ \text{eardrum: } -15.6, 1.93;\ \text{structure: } -23.8, 2.92;\ \text{glass: } -18.1, 2.79), \quad V_{burn} = \frac{t_eI^{4/3}}{10^4}\ (-14.9, 2.56)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p^o\) | Peak overpressure | Pa |
| \(I\) | Thermal radiation intensity | W/m² |
| \(t_e\) | Exposure time to the radiation | s |
| \(P_{lung}\) | Deaths from lung haemorrhage | - |
| \(P_{ear}\) | Eardrum rupture | - |
| \(P_{struct}\) | Structural damage | - |
| \(P_{glass}\) | Glass breakage | - |
| \(P_{burn}\) | Burn deaths from flash or pool fire | - |
| \(Y_{burn}\) | Burn probit | - |
Method and standards
Probit model with Eisenberg's constants (p in Pa, I in W/m², t in s).
Where it is used
- Consequence screening for layouts and emergency planning.
- Training.
Common mistakes
- Using kPa in the probit.
- Treating the result as an individual's risk.
Assumptions and limits
- Average population; no shelter.
References
- Crowl and Louvar
- Chemical Process Safety: Fundamentals with Applications
- 2nd ed. (Prentice Hall, 2002)
- ch. 2
- Table 2-5 and eq. 2-6 (Eisenberg probits)
Questions and answers
What is a probit?
A transformed probability: Y = 5 is 50 %, and each unit of Y is one standard deviation of a normal distribution.
Why is overpressure in pascals?
The constants were fitted with overpressure in N/m² (Pa), radiation in W/m² and time in seconds; the calculator converts for you.
What do the defaults represent?
Crowl and Louvar's Example 2-5 overpressure of 21,400 Pa, and 12.5 kW/m² for 30 s.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.