FireCADCalc

Reactor Coolant Pump Coastdown Flow after a Trip

Flow and speed decay of a reactor coolant pump after loss of power from its rotating inertia and rated power, with the half-flow time and the integrated flow.

Thermal power plant

Inputs

Examples: Illustrative 3500 kg m2, 1190 rpm, 5.5 MW, 10 sLight flywheel 1200 kg m2, 30 sSmall pump 50 kg m2, 1480 rpm, 200 kW, 5 s

Accepted: 1 to 1,000,000 kg·m²
Accepted: 9.5493 to 3,819.7 rpm
Accepted: 0.001 to 100 MW
Accepted: 0 to 10,000 s

Results

Hydraulic torque ∝ ω² gives Iω̇ = −(P₀/ω₀)(ω/ω₀)², so ω/ω₀ = W/W₀ = 1/(1 + t/t_p) with t_p = Iω₀²/P₀ (flow ∝ speed by the affinity laws). Friction torque, loop inertia and natural circulation make the real tail differ.

Half-flow (half-speed) time I ω₀²/P₀6.0051s
Flow fraction at t54.567%
Stored kinetic energy at rated speed0.60051MJ
Integrated flow (equivalent full-flow seconds)3.6376s
Time to 10 % flow54.046s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 3500 kg m2, 1190 rpm, 5.5 MW, 10 s. The inputs, in the units selected above:

InputValue
Rotating inertia of pump, motor and flywheel3,500.0 kg·m²
Rated speed1,190.0 rpm
Shaft power at rated speed and flow5.5000 MW
Time after the trip10.000 s

Applying the formula below gives:

ResultValue
Half-flow (half-speed) time I ω₀²/P₀9.8823 s
Flow fraction at t49.704 %
Stored kinetic energy at rated speed27.176 MJ
Integrated flow (equivalent full-flow seconds)6.9086 s
Time to 10 % flow88.940 s

Open this example in the calculator and change any input.

Formula

\(\frac{W}{W_0} = \frac{\omega}{\omega_0} = \frac{1}{1 + t/t_p}, \quad t_p = \frac{I\omega_0^2}{P_0}, \quad \int_0^t\frac{W}{W_0}dt = t_p\ln\left(1 + \frac{t}{t_p}\right)\)

Variables

Symbol Meaning SI unit
\(I\) Rotating inertia of pump, motor and flywheel kg·m²
\(n_0\) Rated speed rad/s
\(P_0\) Shaft power at rated speed and flow W
\(t\) Time after the trip s
\(t_p\) Half-flow (half-speed) time I ω₀²/P₀ s
\(W/W_0\) Flow fraction at t -
\(E_k\) Stored kinetic energy at rated speed J
\(\int W/W_0\,dt\) Integrated flow (equivalent full-flow seconds) s
\(t_{10\%}\) Time to 10 % flow s

Method and standards

Pump coastdown.

Where it is used

  • Loss-of-flow transient screening.
  • Flywheel sizing.

Common mistakes

  • Using motor inertia alone without the flywheel.
  • Assuming flow stops when the pump stops (natural circulation continues).

Assumptions and limits

  • Torque ∝ ω²; no friction or loop inertia.

References

  • Pump coastdown with torque proportional to speed squared

Questions and answers

Why do coolant pumps have flywheels?

After loss of power the flywheel keeps the flow up for the seconds the reactor needs to scram and the decay heat to fall, protecting the fuel against departure from nucleate boiling.

How fast does flow fall?

To half in t_p and to 10 % in about nine t_p; with t_p of several seconds, natural circulation takes over within a minute or two.

What do the defaults represent?

An illustrative pump set with 3,500 kg·m² of inertia at 1,190 rpm and 5.5 MW, 10 seconds after the trip.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.