Worked example
Example: Illustrative 3500 kg m2, 1190 rpm, 5.5 MW, 10 s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rotating inertia of pump, motor and flywheel | 3,500.0 kg·m² |
| Rated speed | 1,190.0 rpm |
| Shaft power at rated speed and flow | 5.5000 MW |
| Time after the trip | 10.000 s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Half-flow (half-speed) time I ω₀²/P₀ | 9.8823 s |
| Flow fraction at t | 49.704 % |
| Stored kinetic energy at rated speed | 27.176 MJ |
| Integrated flow (equivalent full-flow seconds) | 6.9086 s |
| Time to 10 % flow | 88.940 s |
Open this example in the calculator and change any input.
Formula
\(\frac{W}{W_0} = \frac{\omega}{\omega_0} = \frac{1}{1 + t/t_p}, \quad t_p = \frac{I\omega_0^2}{P_0}, \quad \int_0^t\frac{W}{W_0}dt = t_p\ln\left(1 + \frac{t}{t_p}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(I\) | Rotating inertia of pump, motor and flywheel | kg·m² |
| \(n_0\) | Rated speed | rad/s |
| \(P_0\) | Shaft power at rated speed and flow | W |
| \(t\) | Time after the trip | s |
| \(t_p\) | Half-flow (half-speed) time I ω₀²/P₀ | s |
| \(W/W_0\) | Flow fraction at t | - |
| \(E_k\) | Stored kinetic energy at rated speed | J |
| \(\int W/W_0\,dt\) | Integrated flow (equivalent full-flow seconds) | s |
| \(t_{10\%}\) | Time to 10 % flow | s |
Method and standards
Pump coastdown.
Where it is used
- Loss-of-flow transient screening.
- Flywheel sizing.
Common mistakes
- Using motor inertia alone without the flywheel.
- Assuming flow stops when the pump stops (natural circulation continues).
Assumptions and limits
- Torque ∝ ω²; no friction or loop inertia.
References
- Pump coastdown with torque proportional to speed squared
Questions and answers
Why do coolant pumps have flywheels?
After loss of power the flywheel keeps the flow up for the seconds the reactor needs to scram and the decay heat to fall, protecting the fuel against departure from nucleate boiling.
How fast does flow fall?
To half in t_p and to 10 % in about nine t_p; with t_p of several seconds, natural circulation takes over within a minute or two.
What do the defaults represent?
An illustrative pump set with 3,500 kg·m² of inertia at 1,190 rpm and 5.5 MW, 10 seconds after the trip.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990)