Reactor Coolant Flow from Core Power and Loop Temperatures

Reactor coolant mass and volume flow, total and per loop, from core thermal power and the hot-leg and cold-leg temperatures at system pressure.

Thermal power plant

Inputs

Examples: Illustrative four-loop 3000 MWtTwo-loop 1800 MWt, 324/288 CSmall PWR 160 MWt, 1 loop, 12.8 MPa

Accepted: 0.001 to 10,000 MW
Accepted: 0.1 to 30 MPa
Accepted: 6.85 to 366.85 °C
Accepted: 6.85 to 366.85 °C
Accepted: 1 to 8

Results

ṁ = Q/(h_hot − h_cold). Flow through bypass paths (head cooling, guide tubes) is extra; thermal design flow is usually a few per cent below the best-estimate flow. Water and steam properties from IAPWS-IF97.

Total coolant mass flow1,900.7t/h
Mass flow per loop1,900.7t/h
Volume flow per loop at the cold leg2,385.7m³/h
Enthalpy rise across the core303.04kJ/kg
Core temperature rise57.000K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative four-loop 3000 MWt. The inputs, in the units selected above:

InputValue
Core thermal power (plus pump heat if wanted)3,000.0 MW
Primary pressure15.500 MPa
Hot-leg temperature325.00 °C
Cold-leg temperature292.00 °C
Number of loops4.0000 -

Applying the formula below gives:

ResultValue
Total coolant mass flow56,974 t/h
Mass flow per loop14,243 t/h
Volume flow per loop at the cold leg19,186 m³/h
Enthalpy rise across the core189.56 kJ/kg
Core temperature rise33.000 K

Open this example in the calculator and change any input.

Formula

\(\dot m = \frac{Q}{h(p, T_h) - h(p, T_c)}\)

Variables

Symbol Meaning SI unit
\(Q\) Core thermal power (plus pump heat if wanted) W
\(p\) Primary pressure Pa
\(T_h\) Hot-leg temperature K
\(T_c\) Cold-leg temperature K
\(n\) Number of loops -
\(\dot m\) Total coolant mass flow kg/s
\(\dot m_{loop}\) Mass flow per loop kg/s
\(\dot V_c\) Volume flow per loop at the cold leg m³/s
\(\Delta h\) Enthalpy rise across the core J/kg
\(\Delta T\) Core temperature rise K

Method and standards

Primary loop energy balance.

Where it is used

  • Plant heat balance and flow verification.
  • Teaching PWR systems.

Common mistakes

  • Using c_pΔT with a single c_p (c_p changes quickly near 300 °C at 15.5 MPa).
  • Forgetting pump heat in a tight balance.

Assumptions and limits

  • Steady state; single phase.

References

  • Primary circuit energy balance

Questions and answers

How much water does a large PWR circulate?

About 60,000–70,000 t/h for 3,400 MW, roughly 20,000 m³/h per loop in a four-loop plant.

Why is the core temperature rise only about 30 K?

High flow keeps the coolant well below saturation at 15.5 MPa and keeps the clad cool; the steam generators need the hot leg as hot as possible.

What do the defaults represent?

An illustrative four-loop PWR: 3,000 MW, 15.5 MPa, hot leg 325 °C and cold leg 292 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.