Worked example
Example: Illustrative 4.5 %, 150 U, 160 SWU, 50 GWd/t. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Product enrichment | 4.5000 % |
| Tails assay | 0.25000 % |
| Natural uranium price per kg U (as U₃O₈ content) | 150.00 - |
| Conversion price per kg U | 25.000 - |
| Enrichment price per SWU | 160.00 - |
| Fabrication price per kg of enriched U | 400.00 - |
| Discharge burn-up | 50.000 GWd/t |
| Net plant efficiency | 33.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Natural uranium feed per kg of product | 9.2191 |
| Separative work per kg of product | 6.8711 |
| Cost per kg of enriched uranium in fuel | 3,112.7 |
| Electricity per kg of uranium in fuel | 396.00 MWh |
| Front-end fuel cost per MWh of electricity | 7.8604 |
| Share of uranium purchase in the cost | 44.426 % |
Open this example in the calculator and change any input.
Formula
\(c_{kg} = \frac{F}{P}(c_U + c_{conv}) + \frac{SWU}{P}c_{SWU} + c_{fab}, \quad c_{MWh} = \frac{c_{kg}}{BU\cdot\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_p\) | Product enrichment | - |
| \(x_t\) | Tails assay | - |
| \(c_U\) | Natural uranium price per kg U (as U₃O₈ content) | - |
| \(c_{conv}\) | Conversion price per kg U | - |
| \(c_{SWU}\) | Enrichment price per SWU | - |
| \(c_{fab}\) | Fabrication price per kg of enriched U | - |
| \(BU\) | Discharge burn-up | J/kg |
| \(\eta\) | Net plant efficiency | - |
| \(F/P\) | Natural uranium feed per kg of product | - |
| \(SWU/P\) | Separative work per kg of product | - |
| \(c_{kg}\) | Cost per kg of enriched uranium in fuel | - |
| \(E_e\) | Electricity per kg of uranium in fuel | J |
| \(c_{MWh}\) | Front-end fuel cost per MWh of electricity | - |
| \(c_U F/c_{kg}\) | Share of uranium purchase in the cost | - |
Method and standards
Front-end fuel cost.
Where it is used
- Fuel procurement and generating cost estimates.
- Comparing enrichment and tails options.
Common mistakes
- Pricing uranium per kg of U₃O₈ instead of U.
- Using thermal instead of electrical MWh.
Assumptions and limits
- Front end only; no carrying charges or back-end costs.
References
- Front-end fuel cycle cost with the separative work value function
Questions and answers
How much does nuclear fuel cost per MWh?
About 5–10 per MWh of electricity at recent prices, a small share of total generating cost; uranium itself is roughly half of it.
Why does burn-up matter?
Higher burn-up gets more energy from each kilogram of fabricated, enriched fuel, cutting the fuel cost per MWh.
What do the defaults represent?
Illustrative prices: uranium 150 and conversion 25 per kg U, 160 per SWU, fabrication 400 per kg, 4.5 % fuel with 0.25 % tails, 50 GWd/t and 33 % efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 4