FireCADCalc

Neutron Activation: Induced Activity after Irradiation and Decay

Activity induced by neutron capture from target mass, abundance, cross-section, flux and irradiation time, after decay, with the saturation activity.

Thermal power plant

Inputs

Examples: Illustrative 1 g Co-59, 1e12 n/cm2 s, 30 d, 7 d decaySodium-24 from 10 g NaCl, 0.53 b, 2 h, 1 h decayGold foil 0.1 g, 98.7 b, saturation run 30 d

Accepted: 1E-9 to 10,000,000 g
Accepted: 1 to 260 kg/kmol
Accepted: 0 to 100 %
Accepted: 0.0001 to 10,000 b
Accepted: 1 to 1E+16 1/(cm²·s)
Accepted: 3.169E-11 to 3.169E+10 a
Accepted: 0 to 115,740 d
Accepted: 0 to 115,740 d

Results

A = Nσφ(1 − e^(−λt_i))e^(−λt_d), neglecting burn-up of target and product (valid when σφt_i ≪ 1). Irradiating for one half-life gives 50 % of saturation, two give 75 %.

Target nuclei1.0219e+22
Reaction rate Nσφ (saturation activity)380.13GBq
Activity at the end of irradiation4.0834GBq
Activity after the decay time4.0731GBq
Fraction of saturation reached1.0742%
Specific activity of the element after decay4.0731GBq/g

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1 g Co-59, 1e12 n/cm2 s, 30 d, 7 d decay. The inputs, in the units selected above:

InputValue
Target element mass1.0000 g
Molar mass of the element58.933 kg/kmol
Isotopic abundance of the target nuclide100.00 %
Activation cross-section37.200 b
Neutron flux1.0000e+12 1/(cm²·s)
Half-life of the product5.2714 a
Irradiation time30.000 d
Decay time after irradiation7.0000 d

Applying the formula below gives:

ResultValue
Target nuclei1.0219e+22
Reaction rate Nσφ (saturation activity)380.13 GBq
Activity at the end of irradiation4.0834 GBq
Activity after the decay time4.0731 GBq
Fraction of saturation reached1.0742 %
Specific activity of the element after decay4.0731 GBq/g

Open this example in the calculator and change any input.

Formula

\(A = N\sigma\phi\left(1 - e^{-\lambda t_i}\right)e^{-\lambda t_d}, \quad N = \frac{m}{M}N_A\theta\)

Variables

Symbol Meaning SI unit
\(m\) Target element mass kg
\(M\) Molar mass of the element kg/kmol
\(\theta\) Isotopic abundance of the target nuclide -
\(\sigma\) Activation cross-section m²
\(\phi\) Neutron flux 1/(m²·s)
\(T_{1/2}\) Half-life of the product s
\(t_i\) Irradiation time s
\(t_d\) Decay time after irradiation s
\(N\) Target nuclei -
\(R\) Reaction rate Nσφ (saturation activity) Bq
\(A_0\) Activity at the end of irradiation Bq
\(A\) Activity after the decay time Bq
\(A_0/A_{sat}\) Fraction of saturation reached -
\(a\) Specific activity of the element after decay Bq/kg

Method and standards

Activation and decay.

Where it is used

  • Isotope production and activation analysis.
  • Activation of structures, coolant and samples.

Common mistakes

  • Using the element mass without the isotopic abundance.
  • Using a thermal cross-section in a fast spectrum.

Assumptions and limits

  • No burn-up; constant flux; single product.

References

  • Activation equation with saturation and decay

Questions and answers

Why does activity level off?

Production is constant while decay grows with the amount present; after several half-lives decay balances production at the saturation activity Nσφ.

Why does steel near a reactor become radioactive?

Cobalt and other impurities capture neutrons; cobalt-59 becomes cobalt-60, the main source of dose in plant maintenance.

What do the defaults represent?

An illustrative 1 g of cobalt-59 (37.2 b) in 10¹² n/cm²·s for 30 days, then 7 days of decay.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.