FireCADCalc

Gamma Dose Rate from a Point Source, Stay Time and Safe Distance

Dose rate near an unshielded gamma source from its activity and dose-rate constant, with the dose over a time, stay time and distance for a target rate.

Thermal power plant

Inputs

Examples: Illustrative 37 GBq, 3 m, 30 minRadiography Ir-192 1.5 TBq, 10 mGauge 1 GBq Cs-137 at 0.5 m

Accepted: 1E-6 to 1E+9 GBq
Accepted: 0.0001 to 10
Accepted: 0.05 to 10,000 m
Accepted: 0.016667 to 1,666,700 min
Accepted: 1E-4 to 1,000 mSv
Accepted: 0.0036 to 3.6E+9 µSv/h

Results

Inverse-square law Ḋ = ΓA/r² for a point source in air, no shielding or scatter. Γ depends on the nuclide (photons per decay and their energies); use the value published for the nuclide and dose quantity. Time, distance and shielding are the three means of protection.

Dose rate at the distance0.36800mSv/h
Dose over the exposure time0.36800mSv
Stay time to reach the allowed dose3.2609min
Distance for the target dose rate9.5917m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 37 GBq, 3 m, 30 min. The inputs, in the units selected above:

InputValue
Source activity37.000 GBq
Dose-rate constant (mSv per hour at 1 m per GBq; Co-60 about 0.35)0.35000 -
Distance3.0000 m
Exposure time30.000 min
Dose allowed for the task0.10000 mSv
Target dose rate (for safe distance)2.5000 µSv/h

Applying the formula below gives:

ResultValue
Dose rate at the distance1.4389 mSv/h
Dose over the exposure time0.71944 mSv
Stay time to reach the allowed dose4.1699 min
Distance for the target dose rate71.972 m

Open this example in the calculator and change any input.

Formula

\(\dot D = \frac{\Gamma A}{r^2}, \quad t_s = \frac{D_{lim}}{\dot D}, \quad r_t = r\sqrt{\frac{\dot D}{\dot D_t}}\)

Variables

Symbol Meaning SI unit
\(A\) Source activity Bq
\(\Gamma\) Dose-rate constant (mSv per hour at 1 m per GBq; Co-60 about 0.35) -
\(r\) Distance m
\(t\) Exposure time s
\(D_{lim}\) Dose allowed for the task Gy
\(\dot D_t\) Target dose rate (for safe distance) Gy/s
\(\dot D\) Dose rate at the distance Gy/s
\(D\) Dose over the exposure time Gy
\(t_s\) Stay time to reach the allowed dose s
\(r_t\) Distance for the target dose rate m

Method and standards

Inverse-square dose rate.

Where it is used

  • Industrial radiography and gauge work planning.
  • Source transport and storage boundaries.

Common mistakes

  • Using the constant for a different nuclide or dose quantity.
  • Applying it inside a scattering room or very close to an extended source.

Assumptions and limits

  • Point source; no attenuation or scatter.

References

  • Inverse-square law with a specific gamma-ray dose-rate constant

Questions and answers

How quickly does dose rate fall with distance?

With the square of distance: doubling the distance cuts the dose rate to a quarter.

What is a typical public limit?

Many regulations use 1 mSv per year for the public and set boundary rates such as 2.5 µSv/h for controlled areas; check the rules that apply.

What do the defaults represent?

An illustrative 37 GBq (1 Ci) source with Γ = 0.35 mSv·m²/(h·GBq), a worker at 3 m for 30 minutes with a 0.1 mSv task limit, and a 2.5 µSv/h boundary.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 9 and 10

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.