Worked example
Example: Illustrative PWR rod at 18 kW/m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Linear heat rate | 18.000 kW/m |
| Pellet radius | 4.1000 mm |
| Radial gap width | 0.080000 mm |
| Cladding thickness | 0.57000 mm |
| Fuel thermal conductivity (UO₂ about 2.5–4) | 3.0000 W/(m·K) |
| Gap conductance | 6,000.0 W/(m²·K) |
| Cladding thermal conductivity (Zircaloy about 17) | 17.000 W/(m·K) |
| Bulk coolant temperature | 310.00 °C |
| Coolant heat transfer coefficient | 34,000 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Volumetric heat generation in the pellet | 340.84 MW/m³ |
| Heat flux at the clad outer surface | 603.11 kW/m² |
| Clad outer surface temperature | 327.74 °C |
| Clad inner surface temperature | 349.28 °C |
| Pellet surface temperature | 465.74 °C |
| Pellet centreline temperature | 943.20 °C |
| Temperature drop across the pellet | 477.46 K |
Open this example in the calculator and change any input.
Formula
\(T_{max} - T_b = q'\left[\frac{1}{4\pi k_f} + \frac{1}{2\pi r_f h_g} + \frac{\ln(r_{co}/r_{ci})}{2\pi k_c} + \frac{1}{2\pi r_{co}h}\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q'\) | Linear heat rate | W/m |
| \(r_f\) | Pellet radius | m |
| \(\delta_g\) | Radial gap width | m |
| \(t_c\) | Cladding thickness | m |
| \(k_f\) | Fuel thermal conductivity (UO₂ about 2.5–4) | W/(m·K) |
| \(h_g\) | Gap conductance | W/(m²·K) |
| \(k_c\) | Cladding thermal conductivity (Zircaloy about 17) | W/(m·K) |
| \(T_b\) | Bulk coolant temperature | K |
| \(h\) | Coolant heat transfer coefficient | W/(m²·K) |
| \(q'''\) | Volumetric heat generation in the pellet | W/m³ |
| \(q''\) | Heat flux at the clad outer surface | W/m² |
| \(T_{co}\) | Clad outer surface temperature | K |
| \(T_{ci}\) | Clad inner surface temperature | K |
| \(T_{fs}\) | Pellet surface temperature | K |
| \(T_{max}\) | Pellet centreline temperature | K |
| \(\Delta T_f\) | Temperature drop across the pellet | K |
Method and standards
Series thermal resistances of a fuel rod.
Where it is used
- Fuel design margins to melting.
- Teaching nuclear heat transfer.
Common mistakes
- Using the clad outer radius for the gap conductance.
- Using a constant fuel conductivity at very high power.
Assumptions and limits
- Steady state; uniform generation; constant properties.
References
- Radial conduction in a fuel rod with uniform heat generation
Questions and answers
Why is the pellet drop independent of radius?
ΔT = q'/(4πk): for a given linear heat rate, a fatter pellet generates the same heat per metre at a lower density; the two effects cancel.
Where is the largest temperature drop?
In the UO₂ pellet: its conductivity is only about 3 W/(m·K), so 18 kW/m gives a drop of nearly 500 K.
What do the defaults represent?
An illustrative PWR rod at 18 kW/m: 4.1 mm pellet radius, 0.08 mm gap at 6,000 W/(m²·K), 0.57 mm Zircaloy cladding, coolant 310 °C at 34,000 W/(m²·K).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.